MIR spectroscopy versus MALDI-ToF-MS for authenticity control of honeys from different botanical origins based on soft independent modelling by class analogy (SIMCA) - A clash of techniques?
Related Experiment Video
Updated: Oct 26, 2025

MALDI-Mass Spectrometric Imaging for the Investigation of Metabolites in Medicago truncatula Root Nodules
Published on: March 5, 2014
Rebecca Brendel1, Sebastian Schwolow2, Natalie Gerhardt3
1Institute for Instrumental Analytics and Bioanalytics, Mannheim University of Applied Sciences, Paul-Wittsack-Straße 10, 68163 Mannheim, Germany; Institute of Food Chemistry, Hamburg School of Food Science, University of Hamburg, Grindelallee 117, 20146 Hamburg, Germany; Micro-Biolytics GmbH, Schelztorstraße 54, 73728 Esslingen am Neckar, Germany.
Abstract:
In this study, highly reproducible MIR spectroscopy and highly sensitive MALDI-ToF-MS data were directly compared for the metabolomic profiling of monofloral and multifloral honey samples from three different botanical origins canola, acacia, and honeydew. Subsequently, three different classification models were applied to the data of both techniques, PCA-LDA, PCA- kNN, and soft independent modelling by class analogy (SIMCA) as class modelling technique. All monofloral external test set samples were classified correctly by PCA-LDA and SIMCA with both data sets, while multifloral test set samples could only be identified as outliers by the SIMCA technique, which is a crucial aspect in the authenticity control of honey. The comparison of the two used analytical techniques resulted in better overall classification results for the monofloral external test set samples with the MIR spectroscopic data. Additionally, clearly more multifloral external samples were identified as outliers by MIR spectroscopy (91.3%) as compared to MALDI-ToF-MS (78.3%). The results indicate that the high reproducibility of the used MIR technique leads to a generally better ability of separating monofloral honeys and in particular, identifying multifloral honeys. This demonstrates that benchtop-based techniques may operate on an eye-level with high-end laboratory-based equipment, when paired with an optimal data analysis strategy.
More Related Videos
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Resolution Mass Spectrometry (HRMS)

