Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Identification of pesticides in water samples by solid-phase extraction and liquid chromatography-electrospray
Otávio von Ameln Lovison1, Louise Jank2, William Machado de Souza3
1Programa de Pós-graduação em Ciências Farmacêuticas, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil.
Abstract:
The Contaminants of Emerging Concern (CECs), including pesticides, have been a trending topic and Brazil is the country with the highest usage of pesticides worldwide. This study aimed to measure the presence of pesticide residues in the water from different sources in the city of Porto Alegre. We analyzed 55 samples from drinking water treatment plants, public water sites, and sewage treatment plants from winter 2018 to summer 2020 by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry. Among 184 pesticides evaluated, 107 matched validation criteria (linearity, trueness, accuracy, repeatability, reproducibility) and 15 of them were detected in different water samples, including seven insecticides, five antifungals, and three herbicides, with a wide range of toxicity levels and noticeable seasonal differences. For the worst-case scenario evaluation, 20 out of 22 (90.9%) samples exceeded the Risk Quotient of 1. The sum of pesticide concentrations exceeded 100 ng L-1 in 66.7% of samples in February 19 and in 75% of samples in February 20 and the total pesticide concentration has reached the worrisome mark of 1615 and 954.96 ng L-1 respectively. Therefore, our results make evident the need to promote public policies to achieve better water quality monitoring. PRACTITIONER POINTS: Among 184 pesticides evaluated, 107 matched validation criteria (linearity, trueness, accuracy, repeatability, reproducibility). A total of 55 different water samples were analyzed, and 15 pesticides were detected and five quantified. For the worst-case scenario evaluation, 20 out of 21 samples exceeded the Risk Quotient of 1 on Feb/20. The pesticide concentrations sum exceeded 100 ng L-1 in 66.7% of samples on February 19 and in 75% of samples on February 20. It is mandatory to improve water monitoring to guide the development of public policies concerning its quality.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...