Related Experiment Video
Updated: Oct 25, 2025

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Clinical Evaluation of Flowable Composite Materials in Permanent Molars Small Class I Restorations: 3-Year Double
Walter Dukić1, Mia Majić2, Natalija Prica3
1School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia.
Abstract:
This study evaluated the 3-year clinical performance of four different flowable composite materials used in Small Class I restorations in permanent molars. This double-blinded, clinical study analyzed 229 Small Class I restorations/103 children at baseline, 12, 24, and 36 months with modified United States Public Health Services (USPHS) criteria. The tested flowable materials were Voco Grandio Flow + Voco Solobond M, Vivadent Tetric EvoFlow + Vivadent Excite, Dentsply X-Flow + Dentsply Prime&Bond NT, and 3M ESPE Filtek Supreme XT Flow + 3M ESPE Scotchbond Universal. The retention and marginal adaptation rates were highest for Grandio Flow and X Flow materials after 36 months, resulting in the highest score of clinical acceptability at 95.3% and 97.6%, respectively. The Tetric EvoFlow and Filtek Supreme XT Flow had the same retention rate after 36 months at 88.1%. Statistical significance was found in Grandio flow material in postoperative sensitivity criteria (p = 0.021). Tetric EvoFlow showed statistical differences in retention (p = 0.01), color match (p = 0.004), and marginal adaptation (p = 0.042). Filtek Supreme showed statistical differences in retention (p = 0.01) and marginal adaptation (p < 0.001). The flowable composite materials showed excellent clinical efficacy after 36 months of their clinical usage. There was no difference among the tested flowable composite materials quality in Small Class I restorations over time.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:04Confocal Time Lapse Imaging as an Efficient Method for the Cytocompatibility Evaluation of Dental Composites
Published on: November 9, 2014
Related Concept Videos
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...