Application of Three-Dimensional Computed Tomography Improved the Interrater Reliability of the AO/OTA Classification
Seong-Eun Byun1, Oog-Jin Shon2, Jae-Ang Sim3
1Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University, Seongnam 13497, Korea.
Abstract:
We investigated whether interrater reliabilities of the AO/OTA classification of patellar fracture change with the imaging modalities applied, including plain radiography and two- and three-dimensional (2-D and 3-D) computed tomography (CT). Seven orthopedic specialists and four orthopedic residents completed a survey of 50 patellar fractures to classify the fractures according to the AO/OTA classification for patellar fractures. Initially, the survey was conducted using plain radiography only, then with 2-D CT introduced three weeks later and 3-D CT introduced six weeks later. Fleiss' Kappa coefficients were calculated to determine interrater reliability. The overall interrater reliability of the AO/OTA classifications was 0.40 (95% CI, 0.38-0.42) with plain radiography only and 0.43 (95% CI, 0.41-0.45) with the addition of 2-D CT. With the addition of 3-D CT, the reliability was significantly improved to 0.54 (95% CI, 0.52-0.56). In specialists, interrater reliability of the classifications was moderate with all three imaging modalities. With the use of 3-D CT, interrater reliability of the classification was 0.53 (95% CI, 0.50-0.56), which was significantly higher than that with the use of 2-D CT (κ = 0.45; 95% CI, 0.42-0.48). In residents, interrater reliability of the classification was 0.30 (95% CI, 0.24-0.36) with plain radiography. The reliability improved to 0.49 (95% CI, 0.43-0.56) with the addition of 2-D CT, which was significantly higher than that with plain radiography only. The use of 3-D CT imaging improved interrater reliability of the classification. Therefore, surgeons, especially residents, may benefit from using 3-D CT imaging for classifying and planning the treatment of patellar fractures.
Related Concept Videos
Imaging Studies III: Computed Tomography
Classification of Bones
Long and Short Bones
The appendicular skeleton, particularly the upper and lower limbs, is primarily made of long and short bones. The...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...


