Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
Intra-scan inter-tissue variability can help harmonize radiomics features in CT
Hubert Beaumont1, Antoine Iannessi2, Jean Michel Cucchi3
1Median Technologies, 06560, Valbonne, France. Hubert.beaumont@mediantechnologies.com.
Repeatability of radiomics features in CT scans varies by tissue. Relative intra-scan measurements can enhance reliability for quantitative imaging and harmonization across sites.
Area of Science:
- Medical Imaging
- Radiomics
- Quantitative CT
Background:
- Radiomics analysis in computed tomography (CT) is sensitive to variations in acquisition protocols.
- Understanding the repeatability and variability of radiomics features is crucial for reliable quantitative imaging.
Purpose of the Study:
- To assess the repeatability and relative intra-scan variability of radiomics features across different CT acquisition protocols.
- To identify radiomics features suitable for improving tissue characterization and inter-site harmonization.
Main Methods:
- Utilized CT scans from a radiomics phantom and unenhanced abdominal patient series.
- Extracted 9 radiomics features, defining "tandems" as measurements of specific tissues by specific features.
- Assessed variability sources (repetition, protocol, material, patient) and intra-scan correlation.
Main Results:
- Radiomics feature repeatability is material-dependent; 56% of tandems were highly repeatable.
- Histogram-derived radiomics showed lower repeatability; Gray Level Zone Length Matrix (GLZLM) and Gray Level Co-occurrence Matrix (GLCM) features showed high correlation.
- Nearly 60% of relative radiomics measurements exceeded a 0.90 correlation coefficient, enabling paired measurements to improve material/tissue differentiation.
Conclusions:
- Identified specific radiomics features with linearly correlated intra-scan measurements between tissues.
- Relative intra-scan measurements offer a method to improve quantitative imaging reliability on CT.
- Linear correlation property enhances tissue characterization and facilitates inter-site harmonization.
More Related Videos
07:13Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
Published on: October 27, 2023
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT