Accuracy of the independent atom approximation in digital tomosynthesis Monte Carlo simulations
Thomas G Primidis1,2, Vadim Y Soloviev3, Carsten P Welsch1,2
1Department of Physics, University of Liverpool, Liverpool, United Kingdom.
Abstract:
Monte Carlo (MC) codes serve as the gold standard simulation tool during design and optimisation of x-ray imaging systems. Such simulations often model Rayleigh scattering based on the Independent Atom Approximation Model (IAM). This model neglects the low range molecular interference (MI) effects of non-crystalline materials such as human tissues. Previous work has found discrepancies in the simulated images of planar x-ray images between IAM and MI models. However, insignificant differences were found for computed tomography (CT) reconstructions. In this work we present Geant4 MC simulations of a flat panel source digital tomosynthesis (DT) system for human extremities. Results show that with a 1:9 scatter to primary ratio (SPR) in the x-ray projections, the DT reconstructions are insensitive to the differences of the IAM and MI models. Therefore, MC codes that use the IAM model are sufficient for the study of DT systems. That is because DT algorithms have a larger effect on image quality than the few percent change in the noise due to a physical model and noise suppression methods make this change even less important. Dependency of this conclusion on SPR must be considered in other DT modalities where SPR might be larger.
More Related Videos
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Atomic Absorption Spectroscopy: Atomization Methods
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...