Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Enzyme-Linked Immunosorbent Assay01:33

Enzyme-Linked Immunosorbent Assay

15.1K
In 1971, Peter Perlman and Eva Engvall developed an Enzyme-linked immunosorbent assay (ELISA or EIA). ELISA differs from western blot in that the assays are conducted in microtiter plates or in vivo rather than on an absorbent membrane.
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen.  Enzyme-substrate reaction allows the antigen to be visualized or...
15.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Multimodal Information Fusion for Control of Rehabilitation Robots in Motor Dysfunction: A Review.

Bioengineering (Basel, Switzerland)·2026
Same author

Targeting Brain Cholesterol Homeostasis in Alzheimer's Disease: Mechanisms and Therapeutic Perspectives.

Journal of neurochemistry·2026
Same author

Lesional sweat IL-17A reflects local inflammatory activity and treatment response in plaque psoriasis.

The British journal of dermatology·2026
Same author

Corrigendum to "Generation of two induced pluripotent stem cell (iPSC) lines (HZSMHCI001-A and HZSMHCI004-A) from a mother-child dyad with major depressive disorder and bipolar disorder" [Stem Cell Res. 91 (2026) 103920].

Stem cell research·2026
Same author

Single-parameter programmed thermomechanical actuation via 3D-printed helical director fields in liquid crystal elastomers.

Nature communications·2026
Same author

Milk Fat Globules Protect Exogenously Infused Docosahexaenoic Acid-Derived Oxylipins at Low pH Conditions.

Journal of food science·2026
Same journal

Heterojunction-Enhanced Interfacial Evanescent-Tunable Fiber Optic Probe for Amplification-free CRISPR/Cas12a-Based Rapid and Ultrasensitive Detection of MPXV.

Analytical chemistry·2026
Same journal

Tunable Charge Transfer in Europium Metal-Organic Frameworks for Ratiometric Sensing of a Sarin Simulant.

Analytical chemistry·2026
Same journal

A β-Cyclodextrin/Ag<sub>2</sub>O@MWCNT-Based Stochastic Platform for the Simultaneous Molecular Enantiorecognition and Enantioanalysis of Twelve Amino Acids in Biological Matrices.

Analytical chemistry·2026
Same journal

The ACS at 150: The History of Analytical Chemistry Publications and a Century of Progress.

Analytical chemistry·2026
Same journal

Machine Learning-Enabled Image Analysis of Complex Chemical Mixtures: Synthetic Urine Droplets as a Test System.

Analytical chemistry·2026
Same journal

H<sub>2</sub>O<sub>2</sub>/Viscosity Tandem-Locked Fluorescent Probes Based on an In Situ Fluorophore Synthesis Strategy for Colitis Imaging and Diagnosis.

Analytical chemistry·2026
See all related articles

Related Experiment Video

Updated: Oct 25, 2025

Efficient SARS-CoV-2 Quantitative Reverse Transcriptase PCR Saliva Diagnostic Strategy utilizing Open-Source Pipetting Robots
11:11

Efficient SARS-CoV-2 Quantitative Reverse Transcriptase PCR Saliva Diagnostic Strategy utilizing Open-Source Pipetting Robots

Published on: February 11, 2022

4.7K

Sample-to-Answer Robotic ELISA.

Chuqing Zhou1, Zecong Fang1,2,3, Cunyi Zhao4

  • 1Micro-Nano Innovations (MiNI) Laboratory, Department of Biomedical Engineering, University of California, Davis, California 95616, United States.

Analytical Chemistry
|August 11, 2021
PubMed
Summary
This summary is machine-generated.

This article introduces a fully automated, robotic system for performing enzyme-linked immunosorbent assays. By integrating microfluidic chips with nanofibrous membranes, the platform eliminates manual labor, reduces testing time, and maintains high sensitivity for detecting substances like chloramphenicol in small sample volumes.

Keywords:
automated immunoassaynanofibrous membranebioanalytical platformchloramphenicol detection

Frequently Asked Questions

More Related Videos

High Throughput Sequential ELISA for Validation of Biomarkers of Acute Graft-Versus-Host Disease
09:00

High Throughput Sequential ELISA for Validation of Biomarkers of Acute Graft-Versus-Host Disease

Published on: October 31, 2012

16.0K
Automated Acoustic Dispensing for the Serial Dilution of Peptide Agonists in Potency Determination Assays
08:06

Automated Acoustic Dispensing for the Serial Dilution of Peptide Agonists in Potency Determination Assays

Published on: November 10, 2016

7.8K

Related Experiment Videos

Last Updated: Oct 25, 2025

Efficient SARS-CoV-2 Quantitative Reverse Transcriptase PCR Saliva Diagnostic Strategy utilizing Open-Source Pipetting Robots
11:11

Efficient SARS-CoV-2 Quantitative Reverse Transcriptase PCR Saliva Diagnostic Strategy utilizing Open-Source Pipetting Robots

Published on: February 11, 2022

4.7K
High Throughput Sequential ELISA for Validation of Biomarkers of Acute Graft-Versus-Host Disease
09:00

High Throughput Sequential ELISA for Validation of Biomarkers of Acute Graft-Versus-Host Disease

Published on: October 31, 2012

16.0K
Automated Acoustic Dispensing for the Serial Dilution of Peptide Agonists in Potency Determination Assays
08:06

Automated Acoustic Dispensing for the Serial Dilution of Peptide Agonists in Potency Determination Assays

Published on: November 10, 2016

7.8K

Area of Science:

  • Analytical chemistry and Robotic ELISA instrumentation
  • Microfluidics and bioanalytical systems engineering

Background:

Standard immunoassay protocols frequently require significant manual effort and time-intensive steps. These traditional methods often rely on bulky equipment and highly trained personnel to ensure accuracy. Such dependencies create bottlenecks in clinical and research settings. No prior work had resolved the need for a fully autonomous, compact testing solution. This gap motivated the development of integrated platforms to streamline bioanalytical workflows. Prior research has shown that microfluidic integration can enhance assay performance. However, existing systems often lack the flexibility required for diverse diagnostic applications. That uncertainty drove the creation of a programmable, robotic interface for standardized testing.

Purpose Of The Study:

The aim of this research is to develop a fully automated, human-free ELISA platform. Conventional procedures are often hindered by labor-intensive steps and reliance on technician skill. These limitations create a need for innovative, programmable solutions in clinical diagnostics. The authors sought to integrate robotic interfaces with microfluidic technology to address these challenges. By creating a modular system, they intended to improve testing timeliness and consistency. This motivation stems from the requirement for reliable diagnostics in resource-limited or high-risk environments. The study focuses on replacing manual operations with high-precision, automated fluidic control. Researchers designed the system to provide a complete sample-to-answer workflow for various analytical applications.

Main Methods:

The study design centers on a robotic-microfluidic interface to manage bioanalytical tasks. Researchers developed a modular chip architecture to house the nanofibrous membrane. This approach replaces manual pipetting with pneumatically controlled liquid handling. The team implemented back-and-forth flow cycles to facilitate efficient mixing and analyte enrichment. Integrated machine vision hardware captures colorimetric data for automated analysis. The review approach evaluates the system performance against conventional immunoassay standards. Testing protocols focused on detecting chloramphenicol to validate the platform capabilities. Scientists measured the limit of detection and processing time to confirm operational efficiency.

Main Results:

The platform achieved a detection limit of 0.1 ng/mL for chloramphenicol. This result occurred using a sample volume of only 15 microliters. The total processing time for the assay was 20 minutes. These values represent a significant improvement over standard manual procedures. The system successfully performed all bioanalytical steps without human intervention. Automated fluidic control ensured consistent mixing and washing throughout the test. Machine vision provided reliable colorimetric readouts for all samples. The findings demonstrate that the robotic interface maintains high sensitivity while reducing operational time.

Conclusions:

The authors propose that their robotic platform facilitates autonomous testing with high sensitivity. This system achieves rapid detection of chloramphenicol compared to standard manual procedures. The integration of machine vision allows for reliable colorimetric analysis without human oversight. Modular design features enable the system to function effectively in resource-limited environments. Researchers suggest that this technology minimizes human exposure in high-risk scenarios. Consistent performance is maintained through automated fluidic control and precise sample processing. The findings indicate that programmable microfluidics can replace labor-intensive benchtop operations. Future deployment could address the demand for timely diagnostics in varied settings.

The system utilizes a robotic-microfluidic interface to automate pipetting, mixing, and washing. By employing back-and-forth flow patterns, the platform achieves efficient enrichment, while integrated machine vision provides the final colorimetric readout for the sample-to-answer process.

The platform incorporates a modular hybrid microfluidic chip containing a nanofibrous membrane. This specific component enhances sensitivity, allowing the system to detect analytes at low concentrations within small sample volumes.

Pneumatically driven high-precision pipetting is necessary to replace manual liquid handling. This technical requirement ensures that the system maintains consistent fluid volumes, which is critical for achieving accurate results without human intervention.

Machine vision acts as the primary tool for colorimetric readout. This data type replaces the subjective visual inspection typically performed by technicians, ensuring objective and consistent quantification of the assay results.

The platform achieves a detection limit of 0.1 ng/mL for chloramphenicol. This measurement is obtained using only 15 microliters of sample, demonstrating superior efficiency compared to traditional methods that require larger volumes.

The researchers propose that the modular design allows for deployment in resource-limited settings. They claim this approach provides a viable alternative to conventional methods where human involvement must be minimized.