Related Experiment Video
Updated: Oct 24, 2025

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Surgical "elephant trunk" arch replacement with a branched arch prosthesis: two alternative operative techniques
Carlo Bassano1, Dario Buioni1, Antonio Scafuri1
1OU of Cardiac Surgery, Tor Vergata University Hospital, Rome, Italy.
Introduction:
Elephant trunk repair of the aortic arch cannot be performed with a branched prosthesis.
Aim:
We conceived two different modifications of the original technique to perform an arch replacement with a branched graft, while arranging an adequate landing zone for a subsequent thoracic endovascular aortic repair, without the need of dedicated material.
Material And Methods:
Eight consecutive patients underwent arch replacement with one of our techniques. Five were emergency patients with acute aortic dissection, and 3 suffered chronic expansive disease. The "modified elephant trunk" includes a separate anastomosis of an endo-luminal prosthetic segment in the descending aorta. Subsequently, the branched arch prosthesis is anastomosed to the distal aortic stump with the attached trunk. In the "prophylactic debranching", a tail is left on the distal end of the arch prosthesis, so that the branches for the supra-aortic vessels will remain displaced proximally, allowing a "zone 1" available for landing.
Results:
Three patients experienced transient cerebral deficits (1 transient ischemic attack and post-operative delirium in 2 cases), 1 required re-operation for bleeding and 2 needed prolonged intubation. One died of multi-organ failure.
Conclusions:
Both techniques proved to be easily reproducible, and allow an adequate landing zone for a subsequent endovascular procedure, while retaining the advantages of using a tetra-furcated prosthesis. They are a viable alternative when a hybrid prosthesis cannot be implanted.

