Level of patient comfort and measurement reproducibility of three different probes: A cross-sectional study
Daisy Flores-Rodrigo1, Jonathan Meza-Mauricio2, Belen Retamal-Valdes2
1School of dentistry Universidad Cientifica del Sur, Lima, Peru.
Objective:
To determine the comfort level and reproducibility assessment of the probing pocket depth obtained with three different probes.
Methods:
A cross-sectional clinical study was conducted in accordance with the STROBE standards. Three different types of periodontal probes were selected: (1) University of North Carolina (UNC) probe, (2) World health organization (WHO) probe and (3) UNC12 COLORVUE probe. Three experienced and calibrated periodontists performed periodontal clinical assessments (probing depth) and pain assessment with the visual analogue scale (VAS).
Results:
The clinical evaluations were carried out in 13 volunteers who attended the dental clinic of the Universidad Científica del Sur (Lima, Peru). A total of 2106 periodontal clinical measurements were obtained (702 measurements per examiner). Each examiner evaluated 234 sites for each type of probe. When patient comfort values during the periodontal evaluation performed with the 3 types of probes were compared, the patients evaluated with the UNC12 COLORVUE probe perceived less pain with a mean value of 0.61, followed by the WHO probe and the UNC probe. When evaluating the clinical measurements, the UNC probe was observed to obtain the greatest mean depth on probing 1.4 + 0.5 mm, while with the UNC12 Colorvue probe, the values obtained were 1.1 + 0.3 mm, and with the WHO probe, 1.2 + 0.4 mm.
Conclusions:
Based on the periodontal probe used, experience of the examiner and the patient, we can conclude that the UNC12 Colorvue probe was the instrument that promoted the greatest comfort or the slightest response to pain, followed by the WHO probe. However, the use of the WHO probe resulted in obtaining the lowest reproducibility among depths on probing. The UNC probe produced the highest response to pain in the patients.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...