Related Experiment Video
Updated: Oct 24, 2025

Investigating the Relationship between Sea Surface Chlorophyll and Major Features of the South China Sea with Satellite Information
Published on: June 13, 2020
Comprehensive assessment of MODIS-derived near-surface air temperature using wide elevation-spanned measurements in
Wenjie Zhang1, Baiping Zhang2, Wenbin Zhu2
1Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters, School of Geographical Sciences, Nanjing University of Information Science & Technology, Nanjing 210044, China; Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing 100101, China.
Abstract:
This is the first comprehensive evaluation of the Moderate Resolution Imaging Spectroradiometer (MODIS)-derived near-surface air temperature, which has been used widely in a series of large-scale models varying in various disciplines ranging from climatology, hydrology to ecology. Four retrieval methods: the highest available pressure in the atmospheric profile product, interpolation by the adiabatic lapse rate, interpolation by the hypsometric equation and the combination with land surface temperature, were developed in the past, but only with validation in regional scale. All of these are evaluated in this paper against 2168 hourly meteorological recordings with an elevation span of over 5000 m in China. Results show that the method of the highest available pressure exhibits a serious underestimation, especially in areas of high elevation, such as the Tibetan Plateau. Interpolation by the hypsometric equation can only fix the underestimation to a very small extent, while interpolation by the adiabatic lapse rate can achieve a relatively good performance. In addition to the elevation influence, substantially variable estimates occur with the parabola-like distribution in low elevation areas, which implies the influence of cloud in Southern China. The combination of the underestimation from interpolation by the adiabatic lapse rate and overestimation in land surface temperature can eliminate the disturbance of both elevation and cloud, resulting in the best performance with r = 0.94, bias = -0.83°C and root-mean-square-error = 4.18°C.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

