Related Experiment Video
Updated: Oct 23, 2025

Failure of Cleaning Verification in Pharmaceutical Industry Due to Uncleanliness of Stainless Steel Surface
Published on: August 11, 2017
Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross
Somayeh Lamei Ramandi1, Ramin Asgharian2
1Department of Analytical Chemistry, Faculty of Chemistry, Islamic Azad University, North Tehran Branch, Iran.
Abstract:
The historical approaches that have been used to establish cleaning validation acceptance limits should be updated to recent approaches to prevent cross contamination. In the present investigation, a cleaning method was validated using high performance liquid chromatography. Method modification critical parameters including spiking, swab sampling from PVC, Stainless Steel, and Polyethylene, extraction technique from swab, solubility, potency, toxicity (LD50), and improvement of limit of detection (LOD) of the method through analytical method validation were studied. In addition, roughness, mechanical and electro-polishing, consideration of dosage form as a quantitative factor, acceptable daily exposure (ADE), and permitted daily exposure (PDE) in the worst-case determination were considered in the study. The method was validated based on USP and ICH guidelines for specificity, limit of detection, limit of quantitation, precision, accuracy, linearity, and range. Linear regression analysis of data for the calibration plot in the range of 7.43, 10.89, 21.78, 43.56, 87.12 µg/mL, and relative standard deviation (R.S.D.) found to be 0.5, 0.4, 0.2, and 0.2, respectively with correlation coefficient of R2 = 0.999997. The LOD and the limit of quantitation (LOQ) were 2.23 and 7.43 µg/mL, respectively. Good recoveries in the range of 73.65-81.20%, and precision with relative standard deviation values lower than 15% have been obtained. The proposed method developed for cleaning validation is specific, precise, and useful for determination of cleaning acceptance limits using health-based limit and Quality Risk Management to develop an appropriate cleaning program for engineering design, safety of patients, and worker protection.
More Related Videos
10:10Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface
Published on: February 23, 2020
09:30Author Spotlight: Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Chemical Agents for Microbial Control
Types of Toxins
Air pollutants, primarily gases, pose significant threats to respiratory health, leading to conditions like hypoxia, lung cancer, and in extreme cases, death.
Environmental pollutants like...
Methods for Controlling Microbial Growth