Related Experiment Video
Updated: Oct 23, 2025

Surgical Closure of Equine Abdomen, Prevention, and Management of Incisional Complications
Published on: May 10, 2024
Influence of preconstructed effector loop location using a barbed unidirectional suture on leakage pressures
Yi-Jen Chang1, Daniel J Duffy1, George E Moore2
1Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina, USA.
Objective:
To evaluate the influence of preconstructed effector loop location using a barbed unidirectional suture on leakage pressures following canine enterotomy closure.
Study Design:
Randomized, experimental, cadaveric.
Animals Or Sample Population:
Grossly normal jejunal segments from three canine cadavers.
Methods:
Jejunal segments were harvested and randomly assigned based upon effector loop location from the beginning of the incisional line. Groups (n = 12/group) included 0 mm, 5 mm, 10 mm, 15 mm, and intact controls (n = 6/group), repaired using a 3-0 unidirectional barbed suture in a simple continuous pattern. Initial leakage pressure (ILP), maximum intraluminal pressure (MIP), repair time, and leakage location were recorded.
Results:
Mean ILP for 0 mm group (24.42 ± 8.43 mmHg) was lower (p ≤ .001) compared to all experimental groups with ILP ~40% lower. There was no difference in MIP among experimental groups (p = .239). Repair time increased (p < .0001) as the distance of the effector loop increased ≥5 mm from the beginning of the incisional line. Leakage location differed among groups (p < .001) with leakage in the 0 mm group from the incisional line (75%), compared to leakage from predominantly from the suture holes in other groups, respectively.
Conclusion:
Effector loop location influenced ILP and leakage location. Effector loops placed at the beginning of the incisional line (0 mm) decreased ILP compared to loops placed at 5, 10, and 15 mm.
Clinical Significance:
Effector loop location using a unidirectional barbed suture should be placed ≥5 mm from beginning of the incisional line for enterotomy closure. Further in vivo studies are necessary to determine the clinical significance of these findings.