Effect of intracorneal ring segment implantation on high order aberrations comparing patients with eccentric versus
Philipp Anders1,2, Lisa-Marie Anders1,2, Mohamed Elalfy3
1Institute of Molecular and Clinical Ophthalmology Basel, Basel, Switzerland.
Purpose:
To assess potential differences between central and eccentric cones in the aberrometric corneal profile and in visual and keratometric outcomes 6 months after intracorneal ring segment (ICRS) implantation for keratoconus.
Methods:
This study compared two groups consisting of 12 patients each, with central or eccentric keratoconus who were treated with femtosecond laser-assisted Keraring implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, keratometric readings and higher order aberrations (HOAs) including high order aberrations root mean square (HOARMS), coma, spherical aberration and trefoil were measured preoperatively and 6 months after ICRS implantation.
Results:
Trefoil and spherical aberration were significantly reduced after ICRS implantation compared to preoperative values in eccentric keratoconus (Trefoil, p = 0.0049; Spherical aberration, p < 0.0001). In central keratoconus spherical aberration was reduced not significantly after ICRS implantation compared to preoperative values (p = 0.087). Coma showed a significant reduction in central (p = 0.0001) and in eccentric keratoconus (p = 0.0001). The reduction of spherical aberration in central keratoconus was significantly positively correlated to improvement in UDVA (Pearson's correlation coefficient, r = -0.66; p = 0.02). In eccentric keratoconus there was a significant positive correlation between reduction of trefoil and improvement in UDVA (Spearmans R, r = -0.69; p = 0.01).
Conclusion:
Patients both with central and eccentric keratoconus benefit from ICRS implantation. Specifically, our data provide a slightly higher gain in visual performance for eccentric cones 6 month after ICRS implantation, which is accentuated by a greater reduction in spherical aberration and trefoil. Improvements in UDVA are positively correlated with reductions in HOAs.
More Related Videos
07:29Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Related Concept Videos
Angle Closure Glaucoma: Treatment
Focusing of Light in the Eye