Infection rate treating radial and ulnar fractures using bone plate fixation without antibiotic prophylaxis
H Schmökel1, D Skytte1, M Barsch1
1Evidensia Specialistdjursjukshuset, 734 94, Strömsholm, Sweden.
The Journal of Small Animal Practice
|August 19, 2021
Summary
New titanium locking plates effectively treated radial and ulnar fractures in small dogs and cats. This study found good clinical outcomes and low infection rates without routine antibiotic use.
Area of Science:
- Veterinary Orthopedics
- Small Animal Surgery
- Biomaterials in Veterinary Medicine
Background:
- Radial and ulnar fractures are common in small breed dogs and cats.
- Traditional treatments may involve peri-operative antibiotic prophylaxis.
- Evaluating novel fixation methods is crucial for improving outcomes.
Purpose of the Study:
- To assess the efficacy and complication rates of 1.5- and 2.0-mm titanium locking plates for treating radial and ulnar fractures.
- To determine the feasibility of using these plates without peri-operative antibiotic prophylaxis.
- To report clinical and radiographic outcomes in small animal patients.
Main Methods:
- Prospective case series involving small breed dogs and cats with closed radial and ulnar fractures.
- Internal fixation using 1.5- or 2.0-mm titanium locking plates.
- Exclusion of peri-operative antibiotic prophylaxis; follow-up until radiographic union.
Main Results:
- Thirty-two fractures in 32 small animals (average weight 3.9 kg) were included.
- All fractures achieved radiographic union with good clinical outcomes observed.
- Superficial infection rate was 0%; deep infection rate was 3.1%.
Conclusions:
- The 1.5- and 2.0-mm titanium locking plate system is effective for simple closed radial and ulnar fractures in small animals.
- Successful treatment was achieved without peri-operative antibiotic prophylaxis.
- The system offers a good clinical outcome with a low infection rate.