Binary Eluent Based Vortex-Assisted Matrix Solid-Phase Dispersion for the Extraction and Determination of
Shanshan Wang1,2, Ye Shang1, Chunxiao Liang1
1State Key Laboratory of Component-Based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China.
Abstract:
A green, flexible, and effective strategy was proposed to quantify four target compounds (muscone, ethyl palmitate, ethyl oleate, and ethylparaben) from musk by binary eluent based vortex-assisted matrix solid-phase dispersion (MSPD) extraction coupled with GC/MS. Single-factor tests and orthogonal design were employed to optimize the MSPD parameters. In addition, the binary eluent system, methanol, and ethyl acetate 3 : 7 (v/v) were used to extract the target analytes. Finally, C 18 was applied as the easily available dispersant and the sample powder was ground for 2 min. Thereafter, the mixture was rapidly extracted with the binary eluents under whirling for 3 min. Eventually, the analysis of the samples was completed within 12 min by GC/MS. All correlation coefficients (r) of four targets were more than 0.9991. The recoveries of all target compounds ranged from 92.8% to 101% while their RSDs were less than 6.94%. There was no significant matrix interference for the analysis. Thus, the combination of vortex-assisted MSPD with GC/MS was considered as a novel, rapid, and environmentally friendly quantitative approach for musk samples.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
