Characteristic evaluation of a simple hand-made semiconductor dosimeter for mammography
Erika Nakajima1, Hiromi Yamashita2, Hitoshi Sato1
1Graduate School of Health Sciences, Ibaraki Prefectural University of Health Sciences, 4669-2 Ami Amimachi, Inashiki, Ibaraki Prefecture 〒300-0394, Japan.
Abstract:
Daily quality control of mammography equipment is important for providing optimal images and determining appropriate doses. To popularise dosimeters, the Measurement Division, the Japanese Society of Radiological Technology hold a seminar on making simple dosimeters. At this seminar, a hand-made dosimeter for mammography (HD-M) can be made at low cost. However, HD-Ms employ semiconductors, and their energy responses are subject to significant variations. This investigation involved the determination of precautions when using HD-Ms, examining their energy response characteristics and measurable energy ranges. HD-M has four types of selectors for response correction. When the selector and the tube voltage were equal, the HD-M readings matched that of the ionisation chamber within 5%. However, in case of target filter combinations and measuring tube voltages that the selector does not support, the HD-M readings differed by up to 53% from the ionisation chamber values. HD-M may use different measurement circuits and semiconductor elements depending on the time of the seminar. In this study, it was clarified that the correction factork, which is the average value of the ratio of the measured value of the ionisation chamber dosimeter to the measured value of HD-M, changes from 0.62 to 1.53 depending on irradiation conditions such as the combination of target filters and the tube voltage. It was demonstrated that HD-M functions sufficiently as a dosimeter for daily management by determining the correction factor using the method proposed in this study.
Related Concept Videos
Biological Effects of Radiation
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...