Handheld Metal Detector Screening for Metallic Foreign Body Ingestion in Children
Published on: September 11, 2018
Gastric Perforation During MRI After Ingestion of Ferromagnetic Foreign Bodies
Nicholas M Glover1, Ryan Roten1
1Desert Regional Medical Center, Department of Emergency Medicine, Palm Springs, California.
Case Presentation:
A 65-year-old male with schizophrenia and intellectual disability ingested what was reported to be two AA batteries, prior to a scheduled magnetic resonance imaging (MRI) study. He developed severe abdominal pain and presented to the emergency department the following day with hypovolemic/septic shock. General surgery retrieved two metal sockets and a clevis pin from the stomach prior to surgical repair of a gastric perforation. This case highlights a rare yet critical outcome of ingesting ferromagnetic foreign bodies prior to an MRI study.
Discussion:
Medical literature on this subject is scarce as indwelling metal foreign bodies are a contraindication to obtaining an MRI. Yet some patients with indwelling metallic foreign bodies proceed with MRI studies due to either challenges in communication such as age, psychiatric/mental debility, or unknowingly having an indwelling metal foreign body. In this case, the patient surreptitiously ingested metal objects prior to obtaining an MRI.
Insights
Ingesting ferromagnetic foreign bodies before magnetic resonance imaging (MRI) can lead to severe complications, including gastric perforation and shock. This case underscores the critical risks associated with MRI in patients with undisclosed or surreptitiously ingested metallic objects.
Area of Science:
- Medical Imaging Safety
- Gastroenterology
- Emergency Medicine
Background:
- Magnetic Resonance Imaging (MRI) is a powerful diagnostic tool, but poses risks with ferromagnetic materials.
- Patients with cognitive or communication impairments may unknowingly or surreptitiously have metallic foreign bodies.
- Ingestion of foreign bodies, especially metallic ones, can lead to severe gastrointestinal complications.
Purpose of the Study:
- To highlight the critical risks of magnetic resonance imaging (MRI) in patients with ingested ferromagnetic foreign bodies.
- To emphasize the importance of thorough patient screening prior to MRI, particularly in vulnerable populations.
- To report a rare case of gastric perforation secondary to ingestion of metallic objects before an MRI.
Main Methods:
- A case presentation of a 65-year-old male with schizophrenia and intellectual disability.
- Review of the patient's presentation with severe abdominal pain and hypovolemic/septic shock post-scheduled MRI.
- Surgical retrieval of ingested metallic foreign bodies (sockets and clevis pin) from the stomach.
Main Results:
- The patient developed hypovolemic/septic shock and gastric perforation after ingesting metallic objects.
- Surgical intervention was required to remove the foreign bodies and repair the gastric perforation.
- The incident occurred prior to a scheduled magnetic resonance imaging (MRI) study.
Conclusions:
- Ingestion of ferromagnetic foreign bodies presents a rare but life-threatening risk during MRI.
- Challenges in communication and patient debility can obscure the presence of metallic foreign bodies, contraindicating MRI.
- Vigilant screening and awareness are crucial to prevent catastrophic outcomes in patients undergoing MRI.
Related Concept Videos
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging