Insights
Sharp recanalization offers a safe and effective method for treating central venous occlusive disease (CVOD) in hemodialysis patients when conventional techniques fail. This approach demonstrates high technical success rates, improving outcomes for patients with complex venous occlusions.
Area of Science:
- Interventional Radiology
- Vascular Surgery
- Nephrology
Background:
- Central venous occlusive disease (CVOD) poses a significant challenge for patients requiring hemodialysis.
- Conventional endovascular techniques may fail to recanalize occluded central veins.
Purpose of the Study:
- To assess the technical feasibility and safety of sharp recanalization for CVOD in hemodialysis patients.
- To evaluate sharp recanalization as an alternative when standard methods are unsuccessful.
Main Methods:
- Sharp recanalization using devices like guidewire ends, Chiba needles, or RUS-100 was employed after conventional technique failure.
- Procedures targeted occluded segments, guiding instruments across the blockage.
Main Results:
- A 92.6% technical success rate was achieved in 27 procedures across 25 patients.
- Guidewire stiff-end was most common (66.7%), while Chiba needles had 100% success (22.2%).
- Minor adverse events (hematoma, chest pain) and major events (pericardial tamponade, effusion) occurred, with patients recovering.
Conclusions:
- Sharp recanalization is a safe and feasible technique for CVOD in hemodialysis patients.
- It offers a high success rate for cases refractory to conventional recanalization methods.
Background:
The purpose of the present study was to evaluate the technical feasibility and safety of sharp recanalization for central venous occlusive disease (CVOD) in patients requiring hemodialysis.
Methods:
Patients with CVOD requiring hemodialysis who had undergone endovascular recanalization using sharp devices, including the stiff end of a guidewire, Chiba needle, or RUS-100 to cross occluded segments after conventional techniques had failed were included. The needle was guided toward a target placed at the opposite end of the occlusion. Although the guidewire was passed though the occlusion, subsequent procedures such as percutaneous transluminal angioplasty could be performed.
Results:
A total of 27 sharp recanalization procedures in 25 patients were performed. Two attempts failed, 1 patient had undergone two separate successful procedures, and 23 procedures in 23 patients were successful. The overall technique success was 92.6%. The stiff end of a guidewire was the first choice for all the procedures, and recanalization was achieved in 18 patients (66.7%). A Chiba biopsy needle was used in six procedures (22.2%), with 100% technical success. A RUPS-100 set was used in two procedures (7.4%), with one aborted because of concern for complications. The occlusion was subsequently crossed using a Chiba needle. Four minor adverse events (two of mediastinal hematoma and two of chest pain) had occurred, and two major adverse events (pericardial tamponade and acute pleural effusion in one patient [4%], treated with the guidewire stiff-end technique, who recovered after drainage) had occurred.
Conclusions:
Sharp recanalization is safe and feasible with high technical success for CVOD in patients requiring hemodialysis who cannot be recanalized using conventional techniques.
Related Concept Videos
Hemodialysis II: Procedure and Complications
Hemodialysis I: Introduction
Hemodialysis III: Nursing Management
Continuous Renal Replacement Therapy
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Venous Thrombosis III: Interprofessional Care