Related Experiment Video
Updated: Oct 22, 2025

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Design Approach for Reducing Cross-Axis Sensitivity in a Single-Drive Multi-Axis MEMS Gyroscope
Hussamud Din1, Faisal Iqbal1, Byeungleul Lee1
1School of Mechatronics Engineering, Korea University of Technology and Education, Cheonan 31253, Korea.
This study introduces a novel ratio-matching method to significantly reduce cross-axis sensitivity (CAS) in microelectromechanical systems (MEMS) gyroscopes. The technique effectively minimizes unwanted signals, enhancing gyroscope accuracy and performance.
Area of Science:
- Microelectromechanical Systems (MEMS)
- Inertial Sensors
- Sensor Design
Background:
- Cross-axis sensitivity (CAS) is a critical performance limitation in microelectromechanical systems (MEMS) gyroscopes, affecting measurement accuracy.
- Existing methods for CAS reduction often involve complex fabrication processes or limited effectiveness.
Purpose of the Study:
- To present a new design technique, the "ratio-matching method," for estimating and reducing CAS in single-drive multi-axis MEMS gyroscopes.
- To validate the proposed method through simulation and experimental verification.
Main Methods:
- Analysis of a simplified single-drive multi-axis MEMS gyroscope using COMSOL Multiphysics.
- Application of the "ratio-matching method" focusing on drive displacement amplitudes and sense frequency differences ratios.
- Validation via simulation by varying coupling spring position and sense frequency difference, and experimental verification on fabricated devices.
Main Results:
- Initial average CAS of 0.301% (x-axis: 0.482%, y-axis: 0.120%) was reduced to an average of 0.045% (x-axis: 0.018%, y-axis: 0.073%) using the ratio-matching method.
- Achieved an 85.1% reduction in average CAS.
- Demonstrated successful validation through simulations and experimental testing.
Conclusions:
- The proposed "ratio-matching method" is an effective technique for significantly reducing cross-axis sensitivity in single-drive multi-axis MEMS gyroscopes.
- This method offers a practical approach to enhance gyroscope performance and reliability.
- The findings are supported by both simulation and experimental results, confirming the methodology's robustness.
Related Concept Videos
Gyroscope
Gyroscope: Precession
Stress Concentrations in Circular Shafts
Eccentric Axial Loading in a Plane of Symmetry
Unsymmetric Bending - Angle of Neutral Axis
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...