Related Experiment Video
Updated: Sep 3, 2026

Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
Evaluation of Radioactivity in Patient Specimens Received in the Core Laboratory at a National Cancer Institute (NCI)
Christopher G Suciu1,2, Max Amurao3, David Luechtefeld3
1Department of Pathology & Immunology, Washington University in St. Louis School of Medicine, St. Louis, MO, USA.
Background:
Biological specimens from patients who have received radiopharmaceuticals are often collected for diagnostic testing and sent to clinical laboratories. Residual radiation has long been assumed to be minimal. However, literature is sparse and may not represent the specimen volumes or spectrum of radionuclides currently seen at National Cancer Institute (NCI)-designated cancer centers. This study examined the radiopharmaceuticals associated with patient specimens received in the hospital core laboratory and assessed the potential risk of external radiation exposure to laboratory personnel.
Methods:
The types and amounts of radiopharmaceuticals administered in a large metropolitan hospital system were retrospectively examined over a 20-month study period. The associated biological specimens sent to the largest core laboratory in the system for testing were evaluated. In addition, manual survey meter assessment of random clinical specimens and weekly wipe tests were performed for 44 weeks, and wearable and environmental dosimeters were placed for 6 months.
Results:
Over 11 000 specimens, collected within 5 physical half-lives of radiopharmaceutical administration, were processed by our laboratory. Manual survey meter assessment of random clinical specimens routinely identified radioactive specimens. If held in a closed palm for >2 min, many samples could potentially deliver a 0.02 mSv effective dose of radiation.
Conclusions:
The laboratory regularly receives radioactive patient specimens without radioactive labels. Although the vast majority of these are blood specimens associated with low-dose diagnostic radiopharmaceuticals, some samples may be capable of delivering a significant amount of radiation. Recommendations for laboratories associated with NCI cancer centers are given.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
12:04Fluorescence-Activated Cell Sorting-Radioligand Treated Tissue (FACS-RTT) to Determine the Cellular Origin of Radioactive Signal
Published on: September 10, 2021
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET