Related Experiment Video
Updated: Oct 22, 2025

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
On the prevalence of flow instabilities from high-fidelity computational fluid dynamics of intracranial bifurcation
M O Khan1, V Toro Arana2, M Najafi3
1Cardiovascular Imaging, Modelling and Biomechanics Lab, Department of Electrical, Computer and Biomedical Engineering, Ryerson University, Ontario, Canada.
Abstract:
High-fidelity computational fluid dynamics (HF-CFD) has revealed the potential for high-frequency flow instabilities (aka "turbulent-like" flow) in intracranial aneurysms, consistent with classic in vivo and in vitro reports of bruits and/or wall vibrations. However, HF-CFD has typically been performed on limited numbers of cases, often with unphysiological inflow conditions or focused on sidewall-type aneurysms where flow instabilities may be inherently less prevalent. Here we report HF-CFD of 50 bifurcation aneurysm cases from the open-source Aneurisk model repository. These were meshed using quadratic finite elements having an average effective spatial resolution of 0.065 mm, and solved under physiologically-pulsatile flow conditions using a well-validated, minimally-dissipative solver with 20,000 time-steps per cardiac cycle Flow instability was quantified using the recently introduced spectral power index (SPI), which quantifies, from 0 to 1, the power associated with velocity fluctuations above those of the driving inflow waveform. Of the 50 cases, nearly half showed regions within the sac having SPI up to 0.5, often with non-negligible power into the 100's of Hz, and roughly 1/3 had sac-averaged SPI > 0.1. High SPI did not significantly predict rupture status in this cohort. Proper orthogonal decomposition of cases with highest SPIavg revealed time-varying energetics consistent with transient turbulence. Our reported prevalence of high-frequency flow instabilities in HF-CFD modelling of aneurysms suggests that care must be taken to avoid routinely overlooking them if we are to understand the highly dynamic mechanical forces to which some aneurysm walls may be exposed, and their prevalence in vivo.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Laminar and Turbulent Flow
Rapidly Varying Flow
Turbulent Flow
Typical Model Studies
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...