Related Experiment Video
Updated: Oct 21, 2025

08:30
X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
14.6K
Pediatric Phantom Dosimetry of a Portable Handheld X-ray Device
Juan F Yepes1, Jackie Hwang2, LaQuia A Vinson3
1Professor, Department of Pediatric Dentistry, Indiana University School of Dentistry, Indianapolis, Indiana.
Summary
Thyroid shielding significantly reduces radiation dose from the Xray2Go handheld X-ray device for pediatric bitewing projections. Operator radiation exposure was minimal, comparable to background levels.
Area of Science:
- Radiological Sciences
- Medical Imaging
- Pediatric Dentistry
Background:
- Handheld X-ray devices offer portability in dental imaging.
- Quantifying radiation dose is crucial for patient safety, especially in pediatric populations.
- The effectiveness of thyroid shielding in reducing radiation exposure from these devices requires evaluation.
Purpose of the Study:
- To quantify radiation dose from the Xray2Go handheld X-ray device for pediatric bitewing and anterior occlusal projections.
- To evaluate the impact of thyroid shielding on effective dose (E) and tissue equivalent doses (HT).
- To assess operator backscatter radiation levels during device use.
Main Methods:
- Utilized a pediatric phantom head with 24 tissue site dosimeters.
- Conducted exposures for bitewing (BW) and maxillary anterior occlusal (AO) projections, with and without thyroid shielding.
- Performed 30 exposures for each projection type and shielding condition.
- Measured operator backscatter radiation using dosimeters on the forehead and hand.
Main Results:
- Thyroid shielding demonstrated a statistically significant reduction in radiation dose at specific tissue sites (thyroid, lymph nodes, muscle) for BW projections.
- A significant decrease in overall effective dose (E) was observed with thyroid shielding.
- Operator backscatter radiation levels were found to be very low, indistinguishable from background radiation.
Conclusions:
- Thyroid shielding is an effective measure to reduce radiation dose during pediatric dental radiography with the Xray2Go device.
- The Xray2Go handheld X-ray device poses minimal radiation risk to the operator.
- Implementing thyroid shielding is recommended for pediatric patients undergoing bitewing radiography.
More Related Videos
Related Concept Videos
Drug Dosing: Infants and Children
52
Pediatric patient dosages diverge from adults due to disparities in body surface area, total body water, and extracellular fluid per kilogram of body weight. The dosing regimen considers the variations in pharmacokinetics and pharmacology across distinct age groups, encompassing preterm newborns, infants, young children, older children, and adolescents. Calculation of pediatric patient doses is predicated on determining body surface area, which exhibits a superior correlation with the child's...
52
X-ray Imaging
8.7K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
8.7K
Biological Effects of Radiation
16.3K
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
16.3K
Pharmacokinetics in Pediatric Patients: Drug Distribution
47
Drug distribution in the pediatric population exhibits unique challenges and considerations due to the physiological differences between children, particularly neonates and infants, and adults. A crucial aspect of pediatric pharmacology is understanding how these differences impact the pharmacokinetics of various drugs, necessitating age-specific dosing strategies to ensure efficacy and safety.Neonates and infants have a higher total body water content, ~75%–90% of their body weight,...
47