Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Fluid Balance and Ventilator-Associated Events Among Patients Admitted to ICUs in China: A Nested Case-Control Study
Wen Wang1,2, Shichao Zhu3, Qiao He1,2
1Chinese Evidence-based Medicine Center and CREAT Group, West China Hospital, Sichuan University, Chengdu, China.
Objectives:
Fluid therapy is an important component of intensive care management, however, optimal fluid management is unknown. The relationship between fluid balance and ventilator-associated events has not been well established. This study investigated the dose-response relationship between fluid balance and ventilator-associated events.
Design:
Nested case-control study.
Setting:
The study was based on a well-established, research-oriented registry of healthcare-associated infections at ICUs of West China Hospital system (Chengdu, China).
Patients:
A total of 1,528 ventilator-associated event cases with 3,038 matched controls, who consistently underwent mechanical ventilation for at least 4 days from April 1, 2015, to December 31, 2018, were included.
Interventions:
None.
Measurements And Main Results:
We calculated cumulative fluid balance within 4 days prior to ventilator-associated event occurrence. A weighted Cox proportional hazards model with restricted cubic splines was used to evaluate the dose-response relationship. A nonlinear relationship between fluid balance and all three tiers of ventilator-associated events, patients with fluid balance between -1 and 0 L had the lowest risk (p < 0.05 for nonlinear test). The risk of ventilator-associated event was significantly higher in patients with positive fluid balance (4 d cumulative fluid balance: 1 L: 1.19; 3 L: 1.92; 5 L: 2.58; 7 L: 3.24), but not in those with negative fluid balance (-5 L: 1.34; -3 L: 1.14; -1 L: 0.98).
Conclusions:
There was nonlinear relationship between fluid balance and all three tiers of ventilator-associated event, with an fluid balance between -1 and 0 L corresponding to the lowest risk. Positive but not negative fluid balance increased the risk of ventilator-associated events, with higher positive fluid balance more likely to lead to ventilator-associated events.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Mechanical Ventilation I: Indication and Settings
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...