Related Experiment Video
Updated: Oct 21, 2025

Author Spotlight: Assessing the Cardiovascular Profile of Patients with Metabolic Syndrome
Published on: September 27, 2024
Estimation of aortic pulse wave velocity based on waveform decomposition of central aortic pressure waveform
Wenyan Liu1, Yang Yao1, Jinzhong Yang1
1College of Medicine and Biological and Information Engineering, Northeastern University, Shenyang 110167, People's Republic of China.
Abstract:
Objective.Aortic stiffness is associated with risk of cardiovascular events. Carotid-femoral pulse wave velocity (cfPWV) is the current noninvasive gold standard for assessing aortic stiffness. However, the cfPWV measurement is challenging, requiring simultaneous signals at the carotid and femoral sites.Approach.In this study, the aortic PWV is estimated using a single radial pressure waveform and compared with cfPWV. 111 subjects' aortic PWVs are estimated from the decomposition of the derived central aortic pressure waveform based on three types of reconstructed flow waveform: the peak of triangular flow waveform based on 30% ejection time (Q30%tri), the peak of triangular flow waveform based on inflection point (Qtri), and averaged flow waveform (Qavg). The central aortic pressure waveform is derived from a radial pressure waveform via a validated transfer function.Main results.TheQavgis used for estimating aortic PWV without the determination of the peak point of the triangular flow waveforms. The estimated aortic PWV shows good agreement with cfPWV. The mean difference ± SD is 0.29 ± 1.50 m s-1(r2 = 0.29,p< 0.001) for theQ30%tri; 0.27 ± 1.40 m s-1(r2 = 0.38,p < 0.001) for theQtri; 0.23 ± 1.39 m s-1(r2 = 0.40,p < 0.001) for theQavg. The correlation between estimated aortic PWV based onQ30%triand measured cfPWV is weak. The results ofQtriandQavgshow no obvious difference.Significance.The proposed method can be used as a less complex way than conventional measurement of cfPWV to further assess arterial stiffness and predict cardiovascular risks or events.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...

