EFFICACY OF HEMOSTATIC AGENTS IN ENDODONTIC SURGERY: A SYSTEMATIC REVIEW AND NETWORK META-ANALYSIS
Ahmad G A Khater1, Faez Saleh Al-Hamed2, Engie M Safwat3
1Faculty of Oral and Dental Medicine, Ahram Canadian University, Egypt..
Objective:
Adequate hemostasis is a critical step in endodontic surgery. It facilitates the procedure and affects the success and prognosis of the operation. This systematic review and network meta-analysis (NMA) aimed to systematically assess the efficacy of hemostatic agents in endodontic surgery and to identify the most effective ones.
Methods:
PubMed, Scopus, Embase, Cochrane Library, Web of Science, ProQuest, and EBSCOhost databases were searched up to December 2020. We included randomized controlled trials (RCTs) evaluating the efficacy of different hemostatic measures in endodontic surgery, and their risk of bias was assessed using Cochrane's randomized trial tool (RoB 2.0). Frequentist network meta-analysis was conducted, with Odds Ratios and 95% confidence intervals (OR, 95% CI) as effect estimates using the "netmeta" package in R. The quality of evidence was assessed using the CINeMA approach.
Results:
Six RCTs involving 353 patients (mean age 48.12 y) were included. NMA revealed that aluminum chloride achieved higher hemostatic efficacy than epinephrine (OR = 2.55, 95% CI [1.41, 4.64]), while there was non-significant difference when compared with PTFE strips + epinephrine (OR = 1.00, 95% CI [0.35, 2.90]), electrocauterization (OR = 2.67, 95% CI [0.84, 8.46]), or ferric sulfate (OR = 8.65, 95% CI [0.31, 240.92]). Of all hemostatic agents, aluminum chloride ranked first in control bleeding during endodontic surgery (P-score = 0.84), followed by PTFE strips + epinephrine (P-score = 0.80), electrocauterization (P-score = 0.34), epinephrine (P-score = 0.34), ferric sulfate (P-score = 0.18). The quality of evidence was very low.
Conclusions:
Based on the limited data, aluminum chloride provides better hemostasis than epinephrine, while there was no significant difference between the remaining hemostatic agents used in endodontic surgery, which could help clinicians choose the hemostatic agent that achieves adequate hemostasis. achieve adequate hemostasis. Given insufficient evidence, future RCTs addressing this evidence gap are required.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Venous Thrombosis III: Interprofessional Care
Introduction to Hemostasis
The three phases of hemostasis involve many clotting factors present in plasma and several substances released by platelets and injured tissue cells. It is a fast, localized,...
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which...