Related Experiment Video
Updated: Oct 21, 2025

Stem Cell Transplantation Strategies for the Restoration of Cognitive Dysfunction Caused by Cranial Radiotherapy
Published on: October 18, 2011
Fully automated planning and delivery of hippocampal-sparing whole brain irradiation
Iris Rusu1, John Roeske2, Abhishek Solanki2
1Department of Radiation Oncology, Loyola University Medical Center, Maywood, IL, 60153 USA.
Abstract:
The goal of this study is to fully automate the treatment planning and delivery process of hippocampal-sparing whole brain irradiation (HS-WBRT) by combining a RapidPlan (RP) knowledge-based planning model and HyperArc (HA) technology. Additionally, this study compares the dosimetric performance of RapidPlan-HyperArc (RP-HA) treatment plans with RP plans and volumetric modulated arc therapy (VMAT) plans. Ten patients previously treated with HS-WBRT using conventional VMAT were re-planned using RP-HA technique and RP model for HS-WBRT. Treatment plans were generated for 30Gy in 3Gy fractions using 6MV photon beam on a TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, CA) equipped with high definition multileaf collimator (HDMLC). Target coverage, homogeneity index (HI), Paddick Conformity index (CI), dose to organs-at-risk (OARs) provided by the 3 planning modalities were compared, and a paired t-test was performed. Total number of monitor units (MU), effective planning time and beam-on-time time were reported and evaluated for each plan. RP-HA plans achieved on average a 4% increase in D98% of PTV, a 26% improvement in HI, a 2.3% increase in CI, when compared to RP plans. Furthermore, RP-HA plans provided on average 11% decrease in D100% of hippocampi when compared to VMAT plans. All RP-HA plans were generated in less than 30 minutes while RP plans took 40 minutes and VMAT plans required on average 9 hours to complete. Regarding beam-on-time time, it was estimated that RP-HA plans take on average 5 minutes to deliver while RP and VMAT plans require 6.5 and 10 minutes, respectively. RP-HA method provides fully automated planning and delivery for HS-WBRT. The auto-generated plans together with automated treatment delivery allow standardization of plan quality, increased efficiency and ultimately improved patient care.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017