Related Experiment Video
Updated: Oct 21, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Stability-indicating reversed-phase-HPLC method development and validation for sacubitril/valsartan complex in the
Velusamy B Subramanian1, Naresh Kumar Katari1, Vijetha Ponnam2
1Department of Chemistry, School of Science, GITAM (deemed to be University) Hyderabad, Rudraram, Sangareddy, Telangana, India.
Abstract:
According to current regulatory guidelines, a stability-indicating method has been developed to determine the impurities in sacubitril (SCB) and valsartan (VLS) tablet dosage forms and perform robustness studies using the design of experiments approach. The present study was initiated to understand quality target product profile, analytical target profile, and risk assessment for method variables that affect the method response. A reversed-phase-HPLC system was equipped with a Phenomenex Gemini-NX C18 column (150 × 4.6 mm, 3 μm) and a photo diode array detector. A gradient mobile phase was used in this research work. The detection was performed at 254 nm; the flow rate was 1.5 mL/min, and the column temperature was maintained at 30°C. The proposed method was validated per the International Council for Harmonisation Q2 (R1) guidelines. The coefficient of correlation was >0.999 for all impurities. The limits of detection and quantification were evaluated for SCB, VLS, and all impurities. The precision and accuracy were obtained for SCB, VLS, and their related impurities. Intra- and inter-day relative standard deviation values were less than 10.0%, and the recoveries of impurities varied between 90.0 and 115.0%. Based on the validation results, the proposed DoE method can estimate SCB and VLS impurities in the finished dosage form.
More Related Videos
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
06:14Optimized LC-MS/MS Method for the High-throughput Analysis of Clinical Samples of Ivacaftor, Its Major Metabolites, and Lumacaftor in Biological Fluids of Cystic Fibrosis Patients
Published on: October 15, 2017
Related Concept Videos
Structure-Activity Relationships and Drug Design
SAR studies the intricate relationship between a drug's chemical structure and biological activity. It focuses on understanding how modifications to a drug's structure can influence...
Data Validation
Key parameters for method validation include:
Clinically Relevant Drug Product Specifications: Methods of Establishment
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
In Vitro Drug Release Testing: Overview, Development and Validation