Related Experiment Video
Updated: Oct 21, 2025

Preparation and High-temperature Anti-adhesion Behavior of a Slippery Surface on Stainless Steel
Published on: March 29, 2018
Decontamination of stainless-steel bowls with 80% (w/v) alcohol for 30 s and 60 s: randomized experimental study
Melissa Santiloni Montanha Ramos1, Patricia Leme Paniguel1, Terue Sadatsune2
1Secretaria Estadual de Saúde do Estado de São Paulo, Hospital das Clínicas, Botucatu, SP, Brazil.
Objective:
to compare the efficacy of 80% (w/v) alcohol, rubbed for 30 and 60 seconds, in the manual processing of stainless-steel wash bowls, after cleaning with running water and neutral detergent.
Method:
experimental study conducted in a hospital in the state of São Paulo, Brazil, on 50 bowls randomly divided into two groups of 25 bowls each for interventions of 30 and 60 seconds of rubbing with 80% (w/v) alcohol.
Results:
based on the microbiological analyses collected, before and after the interventions for both groups, partial efficacy of the disinfectant was observed even when extending rubbing time. In both groups, there was a higher prevalence of survival of Pseudomonas aeruginosa, with 14 strains that were resistant to carbapenems, being, specifically, 11 to imipenem and three to meropenem.
Conclusion:
stainless-steel bed wash bowls decontaminated for reuse by 80% (w/v) alcohol, after cleaning with running water and neutral detergent, showed to be reservoirs of hospital pathogens. The use of bed wash bowls for patients with intact skin would not have worrying consequences, but considering those with non-intact skin and the contamination of professionals' hands, the results in this study justify the search for other decontamination methods or the adoption of disposable bed baths.
More Related Videos
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
07:00Failure of Cleaning Verification in Pharmaceutical Industry Due to Uncleanliness of Stainless Steel Surface
Published on: August 11, 2017
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...