Tailored versus fixed scan delay in contrast-enhanced abdominal multi-detector CT: An intra-patient comparison of
Luigi Camera1, Giuseppina Dell'Aversano-Orabona2, Michele Gambardella1
1Department of Advanced Biomedical Sciences - Section of Diagnostic Imaging, University "Federico II", Naples, Italy(1).
Purpose:
To perform anintra-patient comparison betweena single-pass protocol (SP) and a portal venous phase (PVP) by means ofboth quantitative and qualitative analysis of image quality.
Methods:
Forty patients (31 M; 9F; aged 20-77 years; BMI 23 ± 4 Kg/m2) underwent both a SP and a PVP using a 64-rows multi-detector CT with a median interval time of 56 days (range5-903). All patients underwent i.v. bolus injection (2.0 cc/sec) of 1.7 cc/Kg of a non ionic iodinated contrast-media (370 mgI/ml) with scan delays of 67 ± 8 and 90 s for the SP and the PVP, respectively. Signal- (SNR) and contrast-to-noise ratios (CNR) were calculated for most visceral organs and for both abdominal aorta (AA) and main portal vein (MPV). For qualitative analysis, reproduction of abdominal viscera and vascular structures was blindly evaluated and inter-observer agreement calculated by the weighted Cohen k-analysis.
Results:
Attenuation values (H.U.) of AA (232 ± 53vs180 ± 36) and MPV (215 ± 39vs187 ± 42) were significantly (p < 0.001) higher in the SP than in PVP, respectively. At qualitative analysis, reproduction of mostabdominal viscerawas also significantly sharper (p < 0.001) with the SP than the PVPwith inter-observer agreement scores (k)ranging from 0.60 to 0.88 for all but one imaging criteria.
Conclusions:
As the SP resulted in a significantly higher vascular enhancement and in a sharper reproduction of most abdominal viscera, it may be better suited than a PVP for the CT evaluation of non traumatic acute abdomen.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT