Anisotropic structure property based image reconstruction method for limited-angle computed tomography
Changcheng Gong1,2, Li Zeng3,4
1College of Mathematics and Statistics, Chongqing Technology and Business University, Chongqing, China.
Abstract:
Limited-angle computed tomography (CT) may appear in restricted CT scans. Since the available projection data is incomplete, the images reconstructed by filtered back-projection (FBP) or algebraic reconstruction technique (ART) often encounter shading artifacts. However, using the anisotropy property of the shading artifacts that coincide with the characteristic of limited-angle CT images can reduce the shading artifacts. Considering this concept, we combine the anisotropy property of the shading artifacts with the anisotropic structure property of an image to develop a new algorithm for image reconstruction. Specifically, we propose an image reconstruction method based on adaptive weighted anisotropic total variation (AwATV). This method, termed as AwATV method for short, is designed to preserve image structures and then remove the shading artifacts. It characterizes both of above properties. The anisotropy property of the shading artifacts accounts for reducing artifacts, and the anisotropic structure property of an image accounts for preserving structures. In order to evaluate the performance of AwATV, we use the simulation projection data of FORBILD head phantom and real CT data for image reconstruction. Experimental results show that AwATV can always reconstruct images with higher SSIM and PSNR, and smaller RMSE, which means that AwATV enables to reconstruct images with higher quality in term of artifact reduction and structure preservation.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...