Speed controller-based fuzzy logic for a biosignal-feedbacked cycloergometer
S Aldo Lechuga Ensastiga1, Juvenal Rodríguez-Reséndiz1, Adyr A Estévez-Bén1,2
1Facultad de Ingeniería, Universidad Autónoma de Querétaro, Querétaro, Mexico.
Abstract:
Nowadays, fuzzy-logic systems are implemented to control machinery or processes that previously required human manipulation. The main objective of this research is to propose a controller based on fuzzy-logic that uses bio-signals for decision making. The study presents the implementation of a fuzzy-speed controller for a therapeutic machine called cycloergometer. It is used in patients who require rehabilitation therapy to improve their mobility in the lower body or to increase their relaxation or flexibility. Basic controllers have been developed where the speed is decided through a user interface, and the therapist must constantly increase or decrease the speed according to the condition of the patient. In this paper, the speed of the therapy equipment is adjusted using the heart rate of the patient. In this way, a bio-signal is used to determine whether a person is tired or relaxed. Therefore, a mechanism is obtained that is not subject to the visual criteria of the therapist. A detailed review of the literature illustrates that one of the main limitations of electroencephalography and electromyography recordings is the low signal-to-noise ratio and the fact that the signals captured at the electrodes are a mixture of sources that cannot be observed directly with noninvasive methods. Therefore, it was decided to work with electrocardiogram-based signals for better robustness of the proposed system. The controller output is a voltage signal in PWM, which is determined by the membership and error functions. The behavior of the implemented controller is validated by different experimental tests based on the increase and decrease of the simulated and real heart rate of a patient. Finally, the results obtained and the possible areas of opportunity for the proposed design are discussed.
More Related Videos
11:06A Human-machine-interface Integrating Low-cost Sensors with a Neuromuscular Electrical Stimulation System for Post-stroke Balance Rehabilitation
Published on: April 12, 2016
10:51An Experimental Platform to Study the Closed-loop Performance of Brain-machine Interfaces
Published on: March 10, 2011
Related Concept Videos
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
PID Controller
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...