Related Experiment Video
Updated: Oct 20, 2025

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
Published on: February 12, 2014
Acceleration of reconstruction for compressed sensing based synthetic transmit aperture imaging by using
Jingke Zhang1, Yuanyuan Wang1, Jing Liu2
1Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
Abstract:
Compressed sensing-based synthetic transmit aperture (CS-STA) was previously proposed to recover the full radio-frequency (RF) channel dataset of synthetic transmit aperture (STA) from that of a smaller number of randomly apodized plane wave (PW) transmissions. In this way, the imaging frame rate (FR) and contrast are improved with maintained spatial resolution, compared with those of STA. Because CS-STA reconstruction is repeated for all receive elements and RF samples (with a high sampling frequency), the recovery of STA dataset in RF domain is time-consuming. In the meantime, a large amount of RF data needs to be transferred and stored, resulting in an increase of system complexity and required memory space. In this study, CS-STA is extended to in-phase/quadrature (IQ) domain (with lower sampling frequency) for the recovery of baseband STA IQ dataset to accelerate the CS-STA reconstruction by reducing the amount of data to be processed. More importantly, CS-STA reconstruction using IQ data is of practical importance, as clinical ultrasound systems typically record baseband IQ signal instead of RF signal. Simulations, phantom and in vivo experiments verify the feasibility of CS-STA in IQ domain for the recovery of STA dataset. More specifically, CS-STA using IQ data achieves similar image quality and appreciably improves reconstruction speed (by ∼3 times) compared with that using RF data. These findings demonstrate that IQ-domain CS-STA is capable of relieving the computational and storage burdens, which may facilitate the implementation of CS-STA in practical ultrasound systems.
Related Concept Videos
Reconstruction of Signal using Interpolation
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Upsampling
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...

