High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Direct LC-MS/MS and indirect GC-MS/MS methods for measuring urinary bisphenol A concentrations are comparable
Jillian Ashley-Martin1, Éric Gaudreau2, Pierre Dumas2
1Environmental Health Science and Research Bureau, Healthy Environments and Consumer Branch, Health Canada, Canada.
The direct method for measuring urinary Bisphenol A (BPA) provides higher concentrations than the indirect method. These differences are unlikely to impact health outcome interpretations in biomonitoring.
Area of Science:
- Environmental Health
- Analytical Chemistry
- Biomonitoring
Background:
- Bisphenol A (BPA) is commonly measured in urine via indirect methods involving enzymatic deconjugation and extraction.
- Direct methods measure free and conjugated BPA simultaneously, summing them for total urinary BPA.
- Accurate interpretation of biomonitoring data for risk assessment necessitates statistical comparison between direct and indirect BPA measurement methods.
Purpose of the Study:
- To compare urinary BPA concentrations obtained from direct and indirect measurement methods.
- To analyze duplicate first-trimester urine samples from 1879 pregnant women in the MIREC Study.
Main Methods:
- Urinary BPA concentrations were measured using gas chromatography-tandem mass spectrometry (GC-MS/MS) for the indirect method.
- Free and conjugated BPA were summed for the direct method, measured via liquid chromatography-tandem mass spectrometry (LC-MS/MS).
- Bland-Altman analysis was employed to evaluate method deviations, stratified by urine specific gravity and limit of quantification (LOQ).
Main Results:
- Median urinary BPA concentrations were 0.89 µg/L (direct) and 0.81 µg/L (indirect).
- The direct method yielded results 8.6% higher on average than the indirect method.
- Percent differences varied significantly with urine specific gravity (4.0% for <1.02 vs. 20.3% for ≥1.02) and showed wider agreement limits below the LOQ.
Conclusions:
- This study, the largest comparison of direct and indirect BPA methods, found the direct method yields higher BPA concentrations.
- Findings contrast with previous research suggesting indirect methods underestimate total BPA exposure.
- Observed differences between methods are unlikely to alter health outcome data interpretation in risk assessments.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors