Related Experiment Video
Updated: Oct 19, 2025

Ultrasound Assessment of Endothelial Function: A Technical Guideline of the Flow-mediated Dilation Test
Published on: April 27, 2016
ASSESSMENT OF ENDOTHELIAL DYSFUNCTION IN PREGNANT WOMEN WITH OBESITY AND PREECLAMPSIA
Marta M Zelinka-Khobzey1, Kostiantyn V Tarasenko1, Tetiana V Mamontova1
1POLTAVA STATE MEDICAL UNIVERSITY, POLTAVA, UKRAINE.
In pregnant women with obesity and preeclampsia, vascular endothelial growth factor (VEGF) levels decrease while circulating endothelial microparticles increase, indicating endothelial dysfunction.
Area of Science:
- Reproductive medicine and maternal health.
- Cardiovascular research.
Background:
- Obesity and preeclampsia are significant risk factors for adverse pregnancy outcomes.
- Endothelial dysfunction plays a crucial role in the pathophysiology of preeclampsia.
- Biomarkers are needed to assess endothelial function in high-risk pregnancies.
Purpose of the Study:
- To evaluate serum vascular endothelial growth factor (VEGF) levels.
- To quantify circulating endothelial microparticles (CD32+CD40+) in peripheral blood.
- To correlate these markers with obesity severity and preeclampsia in pregnant women.
Main Methods:
- Enzyme-linked immunosorbent assay (ELISA) for serum VEGF.
- Flow cytometry for CD32+CD40+ circulating endothelial microparticles.
- Study included 122 pregnant women stratified by BMI and preeclampsia status.
Main Results:
- Serum VEGF concentration decreased with increasing obesity severity and preeclampsia.
- Circulating CD32+CD40+ endothelial microparticles increased in pregnant women with obesity and preeclampsia.
- This inverse pattern suggests endothelial dysfunction in this population.
Conclusions:
- Serum VEGF and CD32+CD40+ microparticles are potential reliable markers.
- These markers can help assess the severity of endothelial dysfunction.
- Useful for managing pregnant women with obesity and preeclampsia.
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation