Wavelet Transform Image Enhancement Algorithm-Based Evaluation of Lung Recruitment Effect and Nursing of Acute Respiratory Distress Syndrome by Ultrasound Image
Related Experiment Video
Updated: Oct 19, 2025

Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Wangyan Jin1, Ling Dai1, Liuyan Ge1
1Department of Critical Medicine, The First People's Hospital of Xiaoshan District, Hangzhou 311201, Zhejiang, China.
Abstract:
This study aimed to analyze the application of ultrasound images of lung recruitment (LR) nursing treatment guided by positive-end expiratory pressure (PEEP) in patients with acute respiratory distress syndrome (ARDS). An ultrasound image enhancement algorithm (UIEA) wavelet transform (WT) was constructed, and the soft threshold (ST) and adjacent region average (ARA) were introduced for simulation comparison. In addition, the signal-to-noise ratio (SNR), peak signal-to-noise ratio (PSNR), and running time were undertaken as the evaluation indexes. The WT algorithm was applied to the ultrasound images of 85 ARDS patients before and after PEEP recruitment. The mean artery pressure (MAP), heart rate (HR), and central venous pressure (CVP), peak inspiratory pressure (Ppeak), mean inspiratory pressure (Pmean), dynamic lung compliance (DLC), PCO2, and PaO2/FiO2 of the patients were recorded before and after the LR. The results showed that the signal-to-noise ratio (SNR) (19.67 ± 3.15 dB) and PSNR (23.08 ± 2.08 dB) of the images enhanced by the WT algorithm were much higher than those of ST (13.88 ± 2.74 dB and 14.62 ± 1.76 dB, respectively) and ARA (14.96 ± 3.06 dB and 15.11 ± 1.94 dB, respectively), while the running time was in adverse (P < 0.05); the HR and CVP of patients after LR nursing treatment were increased greatly, while the MAP was in the opposite case (P < 0.05); after LR nursing treatment, Ppeak, Pmean, DLC, PCO2, and PaO2/FiO2 of the patient were significantly greater than those before the LR, and the difference was statistically significant (P < 0.05). In short, the WT algorithm not only enhanced the quality of ultrasound images but also shortened the running time and improved the processing efficiency. PEEP LR nursing treatment could effectively improve the vascular patency, cardiac ejection capacity, and DLC in patients with ARDS, thereby increasing the airway pressure and maintaining the unobstructed expiration.
Related Concept Videos
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...

