Related Experiment Video
Updated: Oct 19, 2025

Symptom Assessment of Patients with Allergic Rhinitis Using an Allergen Exposure Chamber
Published on: March 3, 2023
Ventilation in worker dormitories and its impact on the spread of respiratory droplets
Kai Zheng1, Peter Ortner1, Yu Wen Lim1
1Architecture and Sustainable Design, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore.
Abstract:
Most of the COVID-19 cases in Singapore have primarily come from foreign worker dormitories. This people group is especially vulnerable partly because of behavioural habits, but the built environment they live in also plays a significant role. These dormitories are typically densely populated, so the living conditions are cramped. The short lease given to most dormitories also means the design does not typically focus on environmental performance, like good natural ventilation. This paper seeks to understand how these dormitories' design affects natural ventilation and, subsequently, the spread of the COVID-19 particles by looking at two existing worker dorms in Singapore. Findings show that some rooms are poorly orientated against the prevailing wind directions, so there is dominant stagnant air in these rooms, leading to respiratory droplets' long residence times. These particles can hover in the air for 10 min and more. Interventions like increased bed distance and removing upper deck beds only showed limited ventilation improvements in some rooms. Comparatively, internal wind scoops' strategic placement was more effective at directing wind towards more stagnant zones. Large canyon aspect ratios were also effective at removing particles from higher elevations.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
External and Internal Respiration
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...

