Preliminary report of post-Ophira mini sling implantation voiding pattern: What to learn from pressure-flow studies?
Lucas Mira Gon1, Danilo Leite Andrade1, Paulo Palma1
1Division of Female Urology, University of Campinas (UNICAMP), Campinas, Brazil.
Background:
The study is amined to correlate the voiding pattern after successful mini sling Ophira implantation with postoperative symptoms and satisfaction, in addition to identifying obstructions.
Materials And Methods:
From 2012 to 2015 in a single institution, all consecutive patients who had stress urinary incontinence treated by using the mini sling Ophira had a pre- and 12 months postoperative urodynamic test. The International Consultation on Incontinence Questionnaire - Urinary Incontinence - Short Form (ICIQ-UI-SF) and the International Consultation on Incontinence Questionnaire - Overactive Bladder (ICIQ-OAB) translated into Portuguese, were given. Patients were objectively considered cured when presenting no urinary incontinence at the Valsalva test and subjectively cured when the ICIQ-UI-SF was zero.
Results:
Questionnaire scores were obtained from 29 patients and urodynamic data from 20 patients. Mini sling Ophira implantation resulted in a significant improvement of urinary symptoms evidenced by a significant mean reduction in ICIQ-UI-SF from 16 to 5 (p < 0.0001) and ICIQ-OAB from 8 to 4 (p = 0.0001). The subjective and objective cure rates were 55% and 45%, respectively. The urodynamic changes were not related to success even when adjusted for age, hormonal status, or anterior pelvic organ prolapse. The mean maximum flow decreased to 4.9 mL/s (95% CI: 0.62-10.8; p = 0.035), and the mean detrusor pressure at maximum flow increased to 11.4 cmH2O (95% CI: 4-18; p = 0.0078).
Conclusions:
Mini sling Ophira implantation decreased maximum urinary flow and increased the detrusor pressure at the maximum urinary flow and these urodynamic changes were not related to success.
More Related Videos
10:19Evaluation of Biomaterials for Bladder Augmentation using Cystometric Analyses in Various Rodent Models
Published on: August 9, 2012
07:41Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Related Concept Videos
Urodynamic Studies: Uroflowmetry
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies II: Ultrasonography