Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Simultaneous Electrical Bio-Impedance Plethysmography at Different Body Parts: Continuous and Non-Invasive Monitoring
Abstract:
A simultaneous and time-synchronized electrical bio-impedance plethysmography (BPG) sensor system is implemented for long-term, continuous, and non-invasive measurement of arterial pulse wave velocity (PWV). The proposed BPG sensor system electrically separates each ground plane of two BPG channels and controller, and the two different BPG channels are time-synchronized by the controller transmitting periodic pulse signal to the two BPG channels. Furthermore, net parasitic capacitance between the ground planes is minimized by removing isolated DC-DC converter, limiting the number of digital capacitive isolators, and adopting optimal layout of the ground planes. The proposed sensor system is integrated on 278cm2 printed circuit board. The sensor system consumes 0.35 W/channel, and outstanding channel-to-channel isolation is expected by coupling factor performance of -77.7 dB. In addition, modified electrode configuration for BPG at chest drastically reduces baseline wandering by respiratory motion artifact, thereby further facilitating long-term, continuous, and non-invasive PWV measurement. As a result, long-term, continuous, and non-invasive PWV measurement more than 95 minutes is successfully performed to pave the way for developing pulse transit time (PTT)-based cuff-less blood pressure (BP) estimation technique.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: