Related Experiment Videos
Apparatus for pasteurising teat cup liners between cows in a herringbone parlour
The Veterinary Record
|January 14, 1978
Summary
A novel back-flushing system effectively cleans teat cup liners in herringbone parlours, eliminating common mastitis-causing bacteria like Staphylococcus aureus and E. coli after just five seconds of hot water treatment.
Area of Science:
- Veterinary Microbiology
- Dairy Science
- Agricultural Engineering
Background:
- Mastitis remains a significant economic concern in dairy herds, often linked to inadequate teat cup liner hygiene.
- Common pathogens such as Staphylococcus aureus, Escherichia coli, Streptococcus agalactiae, and Streptococcus uberis are frequently implicated in mastitis infections.
- Effective cleaning protocols for milking equipment are crucial to prevent pathogen transmission and maintain udder health.
Purpose of the Study:
- To evaluate the efficacy of a novel hot water back-flushing system for cleaning teat cup liners.
- To assess the system's ability to eliminate specific mastitis-causing bacteria from teat cup liners.
- To determine the operational costs and time implications of implementing this cleaning method in a commercial dairy setting.
Main Methods:
- Teat cup liners were deliberately contaminated with Staphylococcus aureus, Escherichia coli, Streptococcus agalactiae, and Streptococcus uberis at a concentration of 10(6) organisms/ml.
- A newly developed back-flushing apparatus was used to treat the contaminated liners with 85°C water for either five or ten seconds.
- Post-treatment, standard swabbing techniques were employed to attempt bacterial recovery from the teat liners.
Main Results:
- Following a five-second back-flush, swabbing failed to recover contaminating organisms in 56 out of 64 tests.
- A ten-second back-flush resulted in no bacterial recovery in the same number of tests.
- The developed apparatus is described, detailing its integration into routine milking procedures.
Conclusions:
- The hot water back-flushing system demonstrates high efficacy in eliminating key mastitis-causing bacteria from teat cup liners.
- The system is operationally feasible, with low running costs (estimated at £4/week for a 100-cow herd) and minimal impact on milking time (approx. 10 seconds per cow).
- Potential improvements in apparatus design and milking techniques are considered for enhanced efficiency and hygiene.