Temporal and Microbiological Analysis of Cardiac Implantable Electrical Device Infections - A Retrospective Study
Yasuo Miyagi1, Shun-Ichiro Sakamoto1, Yasuhiro Kawase1
1Department of Cardiovascular Surgery, Nippon Medical School Tokyo Japan.
Abstract:
Although the causative pathogens in cardiac implantable electronic device (CIED) infections are well known, the relationship between time after implantation and infection patterns has not been sufficiently investigated. This study investigated the microbiology and onset of CIED infections according to infection patterns. This retrospective study included 97 patients who underwent CIED removal due to device-related infections between April 2009 and December 2018. After device implantation, infections peaked in the first year and declined gradually over 10 years. Most infections (>60%) occurred within 5 years. Staphylococcal infections, the predominant form of CIED infections, occurred throughout the study period. CIED infections were categorized as systemic (SI; n=26) or local (LI; n=71) infections according to clinical presentation, and as CIED pocket-related (PR; n=85) and non-pocket-related (non-PR; n=12) infections according to the pathogenic pathway. The main causative pathogen in SI was Staphylococcus aureus, whereas coagulase-negative staphylococci were mainly related to LI. Both SI and LI peaked in the first year after implantation and then decreased gradually. There was no significant microbiological difference between PR and non-PR infections. PR infections showed the same temporal distribution as the overall cohort. However, non-PR infections exhibited a uniform temporal distribution after the first year. The severity of CIED infections depends on the causative pathogen, whereas their temporal distribution is affected by the microbiological intrusion pathway.
Insights
Cardiac implantable electronic device (CIED) infections peak within the first year post-implantation, with most occurring within five years. Staphylococcal infections are common, and infection patterns vary by clinical presentation and pathogen pathway.
Area of Science:
- Cardiology
- Infectious Diseases
- Medical Device Technology
Background:
- Cardiac implantable electronic device (CIED) infections are a significant concern.
- While causative pathogens are known, the temporal patterns of CIED infections require further investigation.
Purpose of the Study:
- To investigate the microbiology and onset of CIED infections based on infection patterns.
- To analyze the relationship between time after CIED implantation and infection characteristics.
Main Methods:
- Retrospective study of 97 patients undergoing CIED removal due to infection (April 2009 - December 2018).
- Categorization of infections into systemic (SI) vs. local (LI) and pocket-related (PR) vs. non-pocket-related (non-PR).
- Analysis of pathogen types and temporal distribution relative to implantation time.
Main Results:
- CIED infections peaked in the first year post-implantation, declining over 10 years, with over 60% occurring within 5 years.
- Staphylococcal infections predominated throughout the study period.
- Systemic infections were mainly caused by *Staphylococcus aureus*, while local infections were associated with coagulase-negative staphylococci. Both SI and LI peaked early.
- Non-pocket-related infections showed a uniform temporal distribution after the first year, unlike pocket-related infections.
Conclusions:
- The temporal distribution of CIED infections is influenced by the microbiological intrusion pathway.
- Infection severity is linked to the causative pathogen, while timing relates to how the pathogen enters the system.