Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Blood pressure assessment with in-ear photoplethysmography
Xiaoman Xing1,2, Zhimin Ma3, Shengkai Xu3
1School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Sciences and Technology of China, Suzhou, Jiangsu, People's Republic of China.
Abstract:
Objective. In this study, we aimed to estimate blood pressure (BP) from in-ear photoplethysmography (PPG). This novel implementation provided an unobtrusive and steady way of recording PPG, whereas previous PPG measurements were mostly performed at the wrist, finger, or earlobe.Methods. The time between forward and reflected PPG waves was very short at the ear site. To minimize errors introduced by feature extraction, a multi-Gaussian decomposition of in-ear PPG was performed. Both hand-crafted and whole-based features were extracted and the best combination of features was selected using a backward-search wrapper method and evaluated by the Akaike information criteria. Hemodynamic parameters such as compliance and inertance were estimated from a four-element Windkessel (WK4) model, which was used to pre-classify PPG signals and generate different BP estimation algorithms. Calibration was done by using previous measurements from the same class. To validate this novel approach, 53 subjects were recruited for a one-month follow-up study, and 17 subjects were recruited for a two-month follow-up study. Calibrated systolic BP estimation accuracy was significantly improved with inertance-based pre-classification, while diastolic BP showed less improvement.Results. With proper feature selection, pre-classification and calibration, we have achieved a mean absolute error of 5.35 mmHg for SBP estimation, compared to 6.16 mmHg if no pre-classification was carried out. The performance did not deteriorate in two months, showing a decent BP trend-tracking ability.Conclusion. The study demonstrated the feasibility of in-ear PPG to reliably measure BP, which represents an important technological advancement in terms of unobtrusiveness and steadiness.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: