Comparison of Flow and Compression Properties of Four Lactose-Based Co-Processed Excipients: Cellactose® 80,

Martin Dominik1, Barbora Vraníková2, Petra Svačinová2

  • 1Department of Pharmaceutical Technology, Faculty of Pharmacy, Masaryk University, Palackého tr. 1946/1, 612 42 Brno, Czech Republic.

Pharmaceutics
|September 28, 2021
PubMed

Related Concept Videos

Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
45
Pharmaceutical Alternatives: Excipients and Impurities-Related Therapeutic Nonequivalence01:19

Pharmaceutical Alternatives: Excipients and Impurities-Related Therapeutic Nonequivalence

Pharmaceutical products contain more than just the active drug; they also contain various excipients such as binders, solubilizers, stabilizers, preservatives, and other elements. In some cases, impurities or contaminants might be present. Traditionally, quality control in pharmaceuticals has primarily focused on the analysis of the active drug, often overlooking the impact of these additional components. The recent issue with heparin contamination by over-sulfated chondroitin sulfate, a...
24
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules01:18

Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules

Bioequivalence in generic drugs, such as tablets and capsules, refers to their pharmaceutical equivalence to the brand-name counterparts. However, for therapeutic equivalence, manufacturers must also consider physical attributes like size, shape, and weight (FDA Guidance for Industry, December 2003). Discrepancies in these aspects could impact patient compliance and cause medication errors. For instance, swallowing difficulties, often experienced with larger tablets or capsules, can lead to...
20
Flow Cytometry01:23

Flow Cytometry

The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
14.4K