Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Real-time B-scan-directed amniocentesis.

L D Platt, F A Manning, M Lemay

    American Journal of Obstetrics and Gynecology
    |March 15, 1978
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Association of human chorionic gonadotropin and post-pregnancy persistent enhanced myometrial vascularity.

    Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology·2026
    Same author

    Continuous non-invasive measurement of core vital signs in the hospital ward.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
    Same author

    Exploring the impact of dance: intersectoral quantitative and qualitative methodological challenges, lessons learned, and recommendations.

    Disability and rehabilitation·2025
    Same author

    A novel smartphone app for blood pressure measurement: a proof-of-concept study against an arterial catheter.

    Journal of clinical monitoring and computing·2022
    Same author

    United States' experience in nuchal translucency measurement: variation according to provider characteristics in over five million ultrasound examinations.

    Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology·2021
    Same author

    Accuracy of automated three-dimensional ultrasound imaging technique for fetal head biometry.

    Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology·2020
    Same journal

    Early patient removal of urinary catheters after urogynecologic surgery, a randomized trial.

    American journal of obstetrics and gynecology·2026
    Same journal

    Standard vs. Lower Pressure Pneumoperitoneum in Laparoscopic Gynecologic Surgery: A Randomized Controlled Trial.

    American journal of obstetrics and gynecology·2026
    Same journal

    Association of Surgical Approach with Oncologic Outcomes in Low-Risk Cervical Cancer.

    American journal of obstetrics and gynecology·2026
    Same journal

    Trends in Infertility Treatments by Race, Ethnicity, Socioeconomic Status, and Region in U.S. Birth Certificates from Live Births: 2011-2022.

    American journal of obstetrics and gynecology·2026
    Same journal

    Likelihood ratios enhance clinical interpretation of metagenomic prediction of early-onset neonatal sepsis in preterm premature rupture of membranes (Letter-to-the-Editor).

    American journal of obstetrics and gynecology·2026
    Same journal

    Taking risk stratification in preterm premature rupture of membranes to the bedside (Reply to Letter-to-the-Editor).

    American journal of obstetrics and gynecology·2026
    See all related articles

    Real-time B scan ultrasound improves amniocentesis success rates, especially in challenging cases. This imaging guidance offers advantages over static methods for obtaining amniotic fluid.

    Area of Science:

    • Obstetrics and Gynecology
    • Medical Imaging
    • Fetal Medicine

    Background:

    • Amniocentesis is a common prenatal diagnostic procedure.
    • Accurate needle placement is crucial for successful amniotic fluid collection.
    • Previous amniocentesis attempts may have failed due to technical difficulties.

    Purpose of the Study:

    • To evaluate the efficacy of real-time B scan ultrasound guidance for amniocentesis.
    • To compare real-time B scan with static B scan methods.
    • To assess the impact of real-time B scan on procedure success and complication rates.

    Main Methods:

    • 150 amniocenteses were performed in 143 patients using real-time B scan ultrasound.
    • Procedures were conducted in the second and third trimesters.

    Related Experiment Videos

  • Success rates, number of attempts, and fluid characteristics were recorded.
  • Main Results:

    • Amniotic fluid was obtained in a single attempt in 146 procedures.
    • Real-time B scan guided successful amniocentesis in patients with prior failed attempts.
    • Using the real-time indicated site resulted in clear fluid, avoiding bloody taps.

    Conclusions:

    • Real-time B scan ultrasound is a reliable method for guiding amniocentesis.
    • It demonstrates comparable reliability to static B scan and offers advantages in specific situations.
    • Real-time imaging enhances procedural success and potentially reduces complications.