A novel smartphone app for blood pressure measurement: a proof-of-concept study against an arterial catheter
G Hofmann1, M Proença2, J Degott3
1Department of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. gregory.hofmann@chuv.ch.
Abstract:
Smartphones may provide a highly available access to simplified hypertension screening in environments with limited health care resources. Most studies involving smartphone blood pressure (BP) apps have focused on validation in static conditions without taking into account intraindividual BP variations. We report here the first experimental evidence of smartphone-derived BP estimation compared to an arterial catheter in a highly dynamic context such as induction of general anesthesia. We tested a smartphone app (OptiBP) on 121 patients requiring general anesthesia and invasive BP monitoring. For each patient, ten 1-min segments aligned in time with ten smartphone recordings were extracted from the continuous invasive BP. A total of 1152 recordings from 119 patients were analyzed. After exclusion of 2 subjects and rejection of 565 recordings due to BP estimation not generated by the app, we retained 565 recordings from 109 patients (acceptance rate 51.1%). Concordance rate (CR) and angular CR demonstrated values of more than 90% for systolic (SBP), diastolic (DBP) and mean (MBP) BP. Error grid analysis showed that 98% of measurement pairs were in no- or low-risk zones for SBP and MBP, of which more than 89% in the no-risk zone. Evaluation of accuracy and precision [bias ± standard deviation (95% limits of agreement)] between the app and the invasive BP was 0.0 ± 7.5 mmHg [- 14.9, 14.8], 0.1 ± 2.9 mmHg [- 5.5, 5.7], and 0.1 ± 4.2 mmHg [- 8.3, 8.4] for SBP, DBP and MBP respectively. To the best of our knowledge, this is the first time a smartphone app was compared to an invasive BP reference. Its trending ability was investigated in highly dynamic conditions, demonstrating high concordance and accuracy. Our study could lead the way for mobile devices to leverage the measurement of BP and management of hypertension.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure