Endoscopically assisted implant removal of a symphyseal pelvic plate - A case report
Stephan Regenbogen1, Markus Beck1, Michael Lang1
1Department for Trauma Surgery, BG Trauma Center Murnau, Murnau, Germany.
Introduction:
The approach-related morbidity rate in the care of pelvic fractures is still high. Endoscopic procedures are known to significantly reduce access-related complications. Recently, a new endoscopically assisted implantation technique for plate osteosynthesis on the anterior pelvic ring has been described as the "Endoscopic Approach to the Symphysis".
Case Report:
We present a case of a 29-year old male with a pelvic injury (AO type 61B2.3a) initially treated with a supraacetabular external fixator. After one week the definitive stabilization was performed by an endoscopically assisted symphyseal plating as well as a percutaneous iliosacral screw on the right side. One year after primary surgery, we performed an endoscopically assisted removal of the symphyseal plate using standard laparoscopic instruments.
Results:
We demonstrate the feasibility of an endoscopically assisted implant removal at the anterior pelvic ring. No complications occurred during the procedure. The patient was discharged after a regular time of surveillance and with an adequate decline of pain.
Discussion:
While we were able to show that the endoscopically assisted implantation as well as the removal of a plate osteosynthesis on the anterior pelvic ring is possible, there is still further research necessary, especially regarding the development of specific endoscopic instruments. This should enable operating times similar to the standard open procedures.