Related Experiment Video
Updated: Oct 18, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Evaluation approach for whole dose distribution in clinical cases using spherical projection and spherical harmonics
Yusuke Anetai1, Yuhei Koike1, Hideki Takegawa1
1Department of Radiology, Kansai Medical University, Shin-machi 2-5-1, Hirakata-shi, Osaka 573-0101, Japan.
Abstract:
Whole dose distribution results from well-conceived treatment plans including patient-specific (location, size and shape of tumor, etc.) and facility-specific (clinical policy and goal, equipment, etc.) information. To evaluate the whole dose distribution efficiently and effectively, we propose a method to apply spherical projection and real spherical harmonics (SH) expansion, thus leading to the expanded coefficients as a rank-2 tensor, SH coefficient tensor, for every patient-specific dose distribution. To verify the feature of this tensor, we introduce Isomap from the manifold learning method and multi-dimensional scaling (MDS). Subsequently, we obtained the MDS distance representing similarity, η, and the SH score, ζ, which is a Frobenius norm of the SH coefficient tensor. These were then validated in the intensity-modulated radiation therapy (IMRT) data sets of: (i) 375 mixing treated regions, (ii) 135 head and neck (HN), and (iii) 132 prostate cases, respectively. The MDS map indicated that the SH coefficient tensor enabled a quantitative feature extraction of whole dose distributions. In particular, the SH score systematically detected irregular cases as the deviation higher than +1.5 standard deviations (SD) from the average case, which matched up with clinically irregular case that required very complicated dose distributions. In summary, the proposed SH coefficient tensor is a useful representation of the whole dose distribution. The SH score from the SH coefficient tensor is a convenient and simple criterion used to characterize the entire dose distributions, which is not dependent on the data set.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Spherical Coordinates
Electric Field of a Non Uniformly Charged Sphere
Consider a non-uniformly charged sphere, for which the density of charge depends only on the distance from a point in space and not on the direction. Such a sphere has a spherically symmetrical charge distribution. Here, the electric...
Gauss's Law: Spherical Symmetry