Calibration of Vector Network Analyzer for Measurements in Radio Frequency Propagation Channels
Published on: June 2, 2020
Calibration methods and facilities for vector receivers using a laser Doppler vibrometer in the frequency range 20 Hz
Guanghui Jia1, Yi Chen2, Shiquan Wang1
1Hangzhou Applied Acoustics Research Institute, No. 82 Guihuaxi Road, Fuyang District, Hangzhou, Zhejiang Province 311400, China.
Abstract:
Calibration methods and facilities have been employed to directly obtain sensitivities of an underwater acoustic vector receiver using two methods based on laser Doppler vibrometry. The vector receiver was first calibrated in a standing wave tube over the frequency range 20 Hz to 2 kHz, where the oscillatory velocity of the water-air interface was measured to determine the sound particle velocity at the position of vector receiver based on waveguide theory. In the frequency range 2.5-10 kHz, the vector receiver was calibrated in an anechoic vessel with dimensions of 1.2 m diameter × 1.8 m length using wideband signals, with a laser Doppler vibrometer used to detect the oscillatory motion of a plastic pellicle, which was sufficiently thin to follow the acoustic particle motion. The uncertainties of the calibration using the optical method were estimated to be 0.7-0.8 dB at 95% confidence interval. The calibration results were compared with those obtained using a reciprocity method in a 50 m × 15 m × 10 m water tank and using a comparison method in a standing wave tube, and the largest deviation did not exceed 1.0 dB over the frequency range 20 Hz to 10 kHz.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Electronic Distance Measuring Instruments
Calibration Curves: Correlation Coefficient
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Doppler Effect - II