Quantitative technetium pyrophosphate and cardiovascular magnetic resonance in patients with suspected cardiac
Golnaz Roshankar1, Geneva C White1, Sebastien Cadet2
1Department of Cardiac Sciences, University of Calgary, GAA08, 3230 Hospital Drive NW, Calgary, AB, T2N 2T9, Canada.
Background:
Quantitation of myocardial 99m Tc-pyrophosphate activity may have high diagnostic accuracy, but its correlation with disease burden is unknown. We examined the relationship between 99m Tc-pyrophosphate quantitation and cardiac magnetic resonance (CMR) measures in patients with suspected transthyretin cardiac amyloidosis (ATTR-CM) or light chain cardiac amyloidosis (AL-CM).
Methods:
Consecutive patients who underwent 99mTc-pyrophosphate imaging and CMR were included. ATTR-CM and AL-CM were diagnosed using standard criteria. 99mTc-pyrophosphate images were assessed with standard parameters and quantified with cardiac pyrophosphate activity (CPA) and volume of involvement (VOI). We assessed the association between 99mTc-pyrophosphate image interpretation and CMR tissue characteristics.
Results:
Seventy patients were identified, mean age 70.4 ± 11.4 years, with ATTR-CM and AL-CM diagnosed in 22 (31%) and 11 (16%) patients, respectively. In patients with ATTR-CM, there were significant correlations between CPA (r2 = 0.509, P < 0.001) and VOI (r2 = 0.586, P < 0.001) with native myocardial T1 mapping values. Additionally, CPA (adjusted hazard ratio (aHR) 1.04, P = 0.016), VOI (aHR 1.12, P = 0.034), and average myocardial T1 (aHR 1.12, P = 0.025) were associated with incidence of heart failure hospitalization or death.
Conclusion:
CPA and VOI were correlated with CMR measures of myocardial fibrosis in patients with ATTR-CM. 99mTc-pyrophosphate quantitation may have a role in ATTR-CM disease staging, guiding treatment, or following response to therapy.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...