Related Experiment Video
Updated: Oct 17, 2025

Author Spotlight: Enhancing Transplantation Research Through MicroCT Angiography in Murine Models
Published on: September 22, 2023
Improvement of Image Quality Using Hybrid Iterative Reconstruction with Noise Power Spectrum Model in Computed
Hiroshi Hamasaki1, Takashi Shirasaka1, Yasuhiro Ushijima2
1Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
Objectives:
In CT during hepatic arteriography (CTHA), the addition of a noise power spectrum (NPS) model to conventional hybrid iterative reconstruction (HIR) may improve spatial resolution and reduce image noise. This study aims at assessing the image quality provided by HIR with a NPS model at CTHA.
Methods:
This institutional review board-approved retrospective analysis included 26 patients with hepatocellular carcinomas (HCCs) who underwent CTHA. In all acquisitions, images were reconstructed with filtered back projection (FBP), adaptive iterative dose reduction 3D (AIDR), and AIDR enhanced (eAIDR) with the NPS model. Four radiologists analyzed the signal-to-noise ratio (SNR) of HCC nodules and its associated feeding arteries. The radiologists used a semiquantitative scale (-3 to +3) to rate the subjective image quality comparing both the FBP and eAIDR images with the AIDR images.
Results:
The feeding arteries' attenuation was significantly higher in eAIDR compared to AIDR [514.3 ± 121.4 and 448.3 ± 107.3 Hounsfield units (HU), p < 0.05]. The image noise of eAIDR was significantly lower than that of FBP (15.2 ± 2.2 and 28.5 ± 4.8 HU, p < 0.05) and comparable to that of AIDR. The SNR of feeding arteries on eAIDR was significantly higher than on AIDR (34.1 ± 7.9 and 27.4 ± 6.3, p < 0.05). Subjective assessment scores showed that eAIDR provided better visibility of feeding arteries and overall image quality compared to AIDR (p < 0.05). The HCC nodule visibility was not significantly different among the three reconstructions.
Conclusion:
In CTHA, eAIDR improved the visibility of feeding arteries associated with HCC nodules without compromising nodule detection.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT