Related Experiment Video
Updated: Oct 17, 2025

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
Published on: March 13, 2017
Measurement accuracy enhancement with multi-event detection using the deep learning approach in Raman distributed
Abstract:
In this work, we present a novel deep learning framework for multi-event detection with enhanced measurement accuracy from the measured data of a Raman Optical Time Domain Reflectometer (Raman-OTDR). We demonstrate the utility of a deep learning-based approach by comparing the results from three popular neural networks, i.e. vanilla recurrent neural network (RNN), long short-term memory (LSTM), and gated recurrent unit (GRU). Before feeding the experimentally obtained data to the neural network, we sanitize our data through a correlation filtering operation to suppress outlier noise spikes. Based on experiments with Raman-OTDR traces consisting of single temperature event, we show that the GRU is able to provide better performance compared to RNN and LSTM models. Specifically, a bidirectional-GRU (bi-GRU) architecture is found to outperform other architectures owing to its use of data from both previous as well as later time steps. Although this feature is similar to that used recently in one dimension convolutional neural network (1D-CNN), the bi-GRU is found to be more effective in providing enhanced measurement accuracy while maintaining good spatial resolution. We also propose and demonstrate a threshold-based algorithm for accurate and fast estimation of multiple events. We demonstrate a 4x improvement in the spatial resolution compared to post-processing using conventional total variational denoising (TVD) filters, while the temperature accuracy is maintained within ± 0.5 oC of the set temperature.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Distance Measurements by Taping
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...

